62-11039
5-6
CONFIGURATION
SELECTIONS
DESCRIPTION
DISPLAY TOTAL SWITCH ON HR
NO /
YES
YES = This hourmeter will be displayed during the
startup messaging sequence and will be in hour-
meter menu.
NO = This hourmeter will not be displayed during
the startup messaging sequence and will be shown
with the “other meters and counters”.
DIESEL RESET VALUE
(Refer to Section 2.9 for oil change
intervals)
0
50 TO 30,000 HRS
in 50 hr increments
0 = The Engine Maintenance Hour Meter is turned
off.
50 – 30,000 hrs = The value selected here will be
the number of hours between engine service inter-
vals.
STANDBY RESET VALUE
0
50 TO 30,000 HRS
in 50 hr increments
0 = The Standby Run Time Maintenance Hour Me-
ter is turned off.
50 – 30,000 hrs = The value selected here will be
the number of hours between standby run time ser-
vice intervals.
SWITCH ON RESET VALUE
0
50 TO 30,000 HRS
in 50 hr increments
0 = The Switch--On Maintenance Hour Meter is
turned off.
50 – 30,000 hrs = The value selected here will be
the number of hours between Switch--On service
intervals.
PM (1--5)
OFF
ENGINE HOURS
SWITCH ON
HOURS
STANDBY HOURS
START CYCLES
HIGH SPEED
HOURS
OFF = The PM 1--5 Maintenance Hour Meter(s) is
turned off.
ENGINE HOURS = PM Meter will count engine
hours until the next service interval.
SWITCH ON HOURS = PM Meter will count Switch
On Hours until the next service interval.
STANDBY HOURS = PM Meter will count Run
Time Hours until the next service interval.
START CYCLES = PM Meter will count how many
times the engine has started until the next service
interval.
HIGH SPEED HOURS = PM Meter will count how
many hours the unit operated in high speed until the
next service interval.
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...