![background image](http://html1.mh-extra.com/html/carrier/vector-1800-mt/vector-1800-mt_operation-and-service-manual_2564194129.webp)
62-11039
6-2
MessageCenter MESSAGES
Message
Description
CONFIG ERROR, REMOVE CARD
There was an error configuring the Micro with the Configuration
PC Card. Remove the PC Card from the slot.
CONFIGS COMPLETE,= TO EXIT
The user has reached the end of the Configurations List. Pressing
the
↑
or
↓
arrow keys will start list over. Press = to exit Configura-
tion List.
CONFIGURATION MODE
Press = to enter Configuration Mode.
CONFIGURATION NOT CHANGED
New configuration selection was not Entered (saved).
CONTINUOUS LOCKED
The current setpoint is within a range that has been locked into the
Continuous Run mode. Start--Stop can not be selected.
CONTINUOUS RUN MODE SELECTED
Continuous run mode is selected.
COPY COMPLETE, REMOVE CARD XX
A DownLoad PC Card has been inserted into the PC Card slot, and
all data from the Data Recorder has been copied onto the PC Card.
You may safely remove PC Card from the slot. XX=number of
empty download slots remaining on the card.
COPY ERROR, REMOVE CARD XX
A DownLoad PC Card has been inserted into the PC Card slot, and
an error occurred while the data was being copied onto the PC
Card. You may safely remove the PC Card from the slot.
XX=number of empty download slots remaining on the card.
COPYING DATA--PLEASE WAIT
A DownLoad PC Card has been inserted into the PC Card slot, and
all data from the Data Recorder is being copied onto the PC Card.
DO NOT REMOVE THE CARD WHILE THIS MESSAGE IS BE-
ING DISPLAYED.
DATA RECORDER FAILURE
The controller has stopped recording unit data.
DEFROST CYCLE STARTED
The unit has gone into defrost.
DOOR OPEN
The trailer compartment door is open.
DOOR OPEN -- LOW SPEED
Shows that the door is open and that the unit is running in low
speed.
ENTERING SERVICE MODE
The initial message for Service Mode.
ERROR: ENG HRS > SWITCH ON HRS
ERROR: HI SP HRS >TOTAL ENG HRS
Incorrect hours have been entered.
ERROR: SBY HRS > SW ON SBY HRS
EVAC / CHARGE MODE
This message will be displayed when the unit is in Service Mode
and the system is ready for recovery and leak testing.
EXITING SERVICE MODE
Service Mode has been turned off and unit is returning to normal
operation.
FUNCTION NOT CHANGED
The = key was not pressed in the allotted amount of time to select
the new Functional Parameter setting. The new setting was not
stored and the old setting will be used.
HOUR METERS NOT CHANGED
Indicates that no changes have been made to the hourmeters in
either the configuration or functional parameter lists.
INACTIVE ALARMS IN MEMORY
There are inactive alarms in the Micro alarm list which have not yet
been cleared out.
INSTALLED, REMOVE CARD XX
An Option PC Card has been inserted into the PC Card slot, and
the option has been installed in the Micro. The PC Card may safely
be removed from the slot. XX indicates number of option installa-
tions remaining on card.
INSTALLING OPTION, PLEASE WAIT
An Option PC Card has been inserted into the PC Card slot, and
the option is being installed in the Micro. DO NOT REMOVE THE
CARD WHILE THIS MESSAGE IS BEING DISPLAYED.
INSTALL STOPPED, REINSERT CARD
An Option PC Card has been inserted into the PC Card slot, and
the install process has been stopped by the PC Card not being fully
inserted in the slot, or by being removed. Remove and reinsert PC
Card to continue.
INTELLI--SLEEP MODE
Sleep Mode and IntelliSleep Intelliset is active. Alternates with
CHANGE INTELLISET TO EXIT at 5 second interval whether unit
is running or not
Summary of Contents for VECTOR 1800 MT
Page 1: ......
Page 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Page 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Page 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Page 21: ...1 7 62 11039 ...
Page 303: ...10 1 62 11039 ...
Page 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Page 311: ...10 9 62 11039 FROM PREVIOUS SHT ...