Chapter 2. Diagnostics
53
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA01D055
DHCP::discover: DHCP decline
DHCP discovery did receive a DHCP offer from one or more
servers that meet the client requirements. However, the client
performed an ARP test on the address and found that
another client was using the address.
The client sent a DHCP decline to the server, but the client
did not receive an additional DHCP offer from a server. The
client still does not have a valid address.
Verify that the DHCP server is functioning properly.
BA01D056
DHCP::discover: unknown DHCP
message
DHCP discovery received an unknown DHCP message type.
Verify that the DHCP server is functioning properly.
BA01D0FF
Closing the DHCP node failed.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA030011
RTAS attempt to allocate memory failed
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA04000F
Self test failed on device; no error or
location code information available
1. If a location code is identified with the error, replace the
device specified by the location code.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA040010
Self test failed on device; can’t locate
package
1. If a location code is identified with the error, replace the
device specified by the location code.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA040020
The machine type and model are not
recognized by the blade server firmware
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA040030
The firmware was not able to build the
UID properly for this system. As a result,
problems may occur with the licensing of
the AIX operating system
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
BA040035
The firmware was unable to find the
“plant of manufacture” in the VPD. This
may cause problems with the licensing
of the AIX operating system.
Verify that the machine type, model, and serial number are
correct for this server. If this is a new server, check for server
firmware updates; then, install the updates if available.
BA040040
Setting the machine type, model, and
serial number failed.
1. Go to “
Checkout procedure
” on page
148
.
2. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...