Chapter 2. Diagnostics
41
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved. If an action solves the problem, then you can stop performing the remaining actions.
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B700 xxxx
Error codes
Description
Action
173A
A VPD collection overflow occurred.
1. Look for and resolve other errors.
2. If there are no other errors:
a. Update the firmware to the current level, as described
in “
Updating the firmware
” on page
231
.
b. You might also have to update the management
module firmware to a compatible level.
173B
A system firmware failure occurred during
VPD collection.
Look for and correct other B1xxxxxx errors.
4091
Informational system log entry only.
No corrective action is required.
4400
There is a platform dump to collect
1. Collect the platform dump information.
2. Go to “
Firmware problem isolation
” on page
185
.
4401
System firmware failure. The system
firmware detected an internal problem.
Go to “
Firmware problem isolation
” on page
185
.
4402
A system firmware error occurred while
attempting to allocate the memory
necessary to create a platform dump.
Go to “
Firmware problem isolation
” on page
185
.
4705
System firmware failure. A problem
occurred when initializing, reading, or
using the system VPD. The Capacity on
Demand function is not available.
Restart the system.
4710
Informational system log entry only.
No corrective action is required.
4714
Informational system log entry only.
No corrective action is required.
4788
Informational system log entry only.
No corrective action is required.
5120
System firmware detected an error
If the system is not exhibiting problematic behavior, you can
ignore this error. Otherwise, go to “
Firmware problem
isolation
” on page
185
.
5121
System firmware detected a programming
problem for which a
platform dump may have been initiated.
1. Collect the event log information.
2. Collect the platform dump information.
3. Go to “
Firmware problem isolation
” on page
185
.
5122
An error occurred during a search for the
load source.
If the partition fails to startup, go to “
Firmware problem
isolation
” on page
185
. Otherwise, no corrective action is
required.
5123
Informational system log entry only.
No corrective action is required.
5190
Operating system error. The server
firmware detected a problem in an
operating system.
Check for error codes in the partition that is reporting the
error and take the appropriate actions for those error codes.
5191
System firmware detected a virtual I/O
configuration error.
1. Use the Integrated Virtual Manager (IVM) to verify or
reconfigure the invalid virtual I/O configuration.
2. Check for server firmware updates; then, install the
updates if available.
5209
Informational system log entry only.
No corrective action is required.
5219
Informational system log entry only.
No corrective action is required.
5300
System firmware detected a failure while
partitioning resources. The
platform partitioning code encountered
an error.
Check the management-module event log for error codes;
then, take the actions associated with those error codes.
5301
User intervention required. The system
detected a problem with the partition
configuration.
Use the Integrated Virtual Manager (IVM) to reallocate the
system resources.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...