128
Escala BL460 -
Problem Determination and Service Guide
SRN Description
FRU/action
A01-07x
System bus parity error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A01-08x
System bus protocol/transfer error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-00x
Error log analysis indicates an error detected
by the memory controller, but the failure
could not be isolated.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-01x
Uncorrectable Memory Error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-03x
Correctable error threshold exceeded.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-04x
Memory Control subsystem internal error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-05x
Memory Address Error (invalid address or
access attempt).
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-06x
Memory Data error (Bad data going to
memory).
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-09x
System bus parity error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-10x
System bus time-out error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-11x
System bus protocol/transfer error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A02-12x
I/O Host Bridge time-out error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...