Chapter 2. Diagnostics
49
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
Error code
Description
Action
BA01000B
The ichapid parameter string exceeds the
maximum length allowed.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
BA01000C
The ichappw parameter string exceeds
the maximum length allowed.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
BA01000D
The iname parameter string exceeds the
maximum length allowed.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
BA01000E
The LUN specified is not valid.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
BA01000F
The chapid parameter string exceeds the
maximum length allowed.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
BA010010
The chappw parameter string exceeds the
maximum length allowed.
The embedded host Ethernet adapters (HEAs) help provide
iSCSI, which is supported by iSCSI software device drivers
on either AIX or Linux. Verify that all of the iSCSI
configuration arguments on the operating system comply
with the configuration for the iSCSI Host Bus Adapter (HBA),
which is the
iSCSI initiator
.
BA010011
SET-ROOT-PROP could not find / (root)
package
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board
and chassis assembly
” on page
229
.
BA010013
The information in the error log entry for
this SRC provides network trace data.
Informational message. No action is required.
BA010014
The information in the error log entry for
this SRC provides network trace data.
Informational message. No action is required.
BA010015
The information in the error log entry for
this SRC provides network trace data.
Informational message. No action is required.
BA010020
A trace entry addition failed because of a
bad trace type.
1. Reboot the blade server.
2. If the problem persists:
a. Go to “
Checkout procedure
” on page
148
.
b. Replace the system-board and chassis assembly, as
described in “
Replacing the Tier 2 system-board and
chassis assembly
” on page
229
.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...