26
Escala BL460 -
Problem Determination and Service Guide
2.4.1.2
6xxxyyyy SRCs
The 6xxxyyyy system reference codes are virtual optical reference codes.
Look for the rightmost 4 characters (
yyyy
in 6xxx
yyyy
) in the error code; this is the
reference code. Find the reference code in
Table 2-5
.
Table 2-5. 6xxxyyyy SRCs
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
6xxxyyyy
Error Codes
Description Action
632Byyyy codes are Network File System (NFS) virtual optical SRCs
632BCFC1
A virtual optical device cannot
access the file containing the list of
volumes.
On this partition and on the Network File System server, verify
that the proper file is specified and that the proper authority is
granted.
632BCFC2
A non-recoverable error was
detected while reading the list of
volumes.
Resolve any errors on the Network File System server.
632BCFC3
The data in the list of volumes is not
valid.
On the Network File System server, verify that the proper file is
specified, that all files are entered correctly, that there are no blank
lines, and that the character set used is valid.
632BCFC4
A virtual optical device cannot
access the file containing the
specified optical volume.
On the Network File System server, verify that the proper file is
specified in the list of volumes, and that the proper authority is
granted.
632BCFC5
A non-recoverable error was
detected while reading a virtual
optical volume.
Resolve any errors on the Network File System server.
632BCFC6
The file specified does not contain
data that can be processed as a
virtual optical volume.
On the Network File System server, verify that all the files specified in
the list of optical volumes are correct.
632BCFC7
A virtual optical device detected an
error reported by the Network File
System server that cannot be
recovered.
Resolve any errors on the Network File System server.
632BCFC8
A virtual optical device encountered
a non-recoverable error.
Install any available operating system updates.
632Cyyyy codes are virtual optical SRCs
632CC000
Informational system log entry only.
No corrective action is required.
632CC002
SCSI selection or reselection timeout
occurred.
Refer to the hosting partition for problem analysis.
632CC010
Undefined sense key returned by
device.
Refer to the hosting partition for problem analysis.
632CC020
Configuration error.
Refer to the hosting partition for problem analysis.
632CC100
SCSD bus error occurred.
Refer to the hosting partition for problem analysis.
632CC110
SCSD command timeout occurred.
Refer to the hosting partition for problem analysis.
632CC210
Informational system log entry only.
No corrective action is required.
632CC300
Media or device error occurred.
Refer to the hosting partition for problem analysis.
632CC301
Media or device error occurred.
Refer to the hosting partition for problem analysis.
632CC302
Media or device error occurred.
Refer to the hosting partition for problem analysis.
632CC303
Media has an unknown format.
No corrective action is required.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...