
Chapter 2. Diagnostics
155
2.8.4
Using the diagnostics program
Follow the basic procedures for running the diagnostics program.
1.
Start the diagnostics from the AIX operating system, from a CD, or from a management
server. See “
Starting AIX concurrent diagnostics
” on page
152
, “
Starting stand-alone
diagnostics from a CD
” on page
152
or “
Starting stand-alone diagnostics from a NIM
server
” on page
153
.
2.
The Function Selection menu is displayed. Use the steps listed to perform one of the
following tasks:
−
Problem Determination
i.
From the Function Selection menu, select Diagnostic Routines and press Enter.
ii.
From the Diagnostic Mode Selection menu, select Problem Determination
iii.
Select the resource to be tested and press F7=Commit.
iv.
Record any results provided and go to “
Service request numbers (SRNs)
” on
page
109
to identify the failure and perform the action(s).
v.
When testing is complete, press F3 to return to the Diagnostic Selection
menu. If you want to run another test, press F3 again to return to the Function
Selection menu.
−
System Verification
i.
From the Function Selection menu, select Diagnostic Routines and press Enter.
ii.
From the Diagnostic Mode Selection menu, select System Verification.
iii.
Select the resource to be tested and press F7=Commit.
iv.
Record any results provided and go to “
Service request numbers (SRNs)
” on
page
109
to identify the failure and perform the action(s).
v.
When testing is complete, press F3 to return to the Diagnostic Selection
menu. If you want to run another test, press F3 again to return to the Function
Selection menu.
−
Task selection
i.
From the Function Selection menu, select Task Selection and press Enter.
ii.
Select the task to be run and press Enter.
iii.
If the Resource Selection List menu is displayed, select the resource on which
the task is to be run and press F7=Commit.
iv.
Follow the instruction for the selected task.
v.
When the task is complete, press F3 to return to the Task Selection List menu.
If you want to run another test, press F3 again to return to the Function
Selection menu.
3.
When testing is complete, press F3 until the Diagnostic Operating Instructions screen is
displayed; then press F3 again to exit the diagnostic program.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...