
178
Escala BL460 -
Problem Determination and Service Guide
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which components are
FRUs.
•
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Isolation
Procedure Code
Symptom Action
FSPSP46
Some corrupt areas of
flash or RAM have
been detected on the
Service Processor.
Replace the system board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
” on page
229
.
FSPSP47
The system has
detected an error
within the PSI link.
Replace the system board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
” on page
229
.
FSPSP48
A diagnostics function
detects an external
processor interface
problem.
If the CRUs called out before this procedure do not fix the problem, Contact
Bull Support.
FSPSP49
A diagnostic function
detects an internal
processor interface
problem.
If the CRUs called out before this procedure do not fix the problem, Contact
Bull Support.
FSPSP50
A diagnostic function
detects a connection
problem between a
processor chip and a
GX chip.
If the CRUs called out before this procedure do not fix the problem, Contact
Bull Support.
FSPSP51
Runtime diagnostics
has detected a
memory bus
correctable error that
is exceeding
threshold. The memory
bus correctable error
does not threaten the
system operation at
the moment. However,
the system is operating
under degraded
mode.
Replace the CRU called out after this FSPSP call. If the CRU that is called out
is a DIMM CRU, perform the following procedure:
1. Replace both memory DIMMs of the pair on the microprocessor that
contains the failing CRU:
DIMM 1 (Px-C1)
For P1-C1, replace DIMMS 1 and 3.
DIMM 2 (Px-C2)
Replace DIMMS 2 and 4.
DIMM 3 (Px-C3)
Replace DIMMS 1 and 3.
DIMM 4 (Px-C4)
Replace DIMMS 2 and 4.
DIMM 5 (Px-C5)
Replace DIMMS 5 and 7.
DIMM 6 (Px-C6)
Replace DIMMS 6 and 8.
DIMM 7 (Px-C7)
Replace DIMMS 5 and 7.
DIMM 8 (Px-C8)
Replace DIMMS 6 and 8.
2. See “
Removing a memory module
” on page
213
for location information
and the removal procedure.
3. Install new memory DIMMs, as described in “
Installing a memory
module
” on page
214
.
See “
Supported DIMMs
” on page
5
for more information.
FSPSP53
A network error has
occurred between the
Service Processor and
the network switch.
Replace the system board and chassis assembly, as described in
“
Replacing the Tier 2 system-board and chassis assembly
” on page
229
.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...