Chapter 2. Diagnostics
133
SRN Description
FRU/action
A10-210
The processor has been deconfigured. The
system is operating in degraded mode.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-00x
A non-critical error has been detected. Error
log analysis indicates an error detected by
the microprocessor, but the failure could not
be isolated.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-01x
A non-critical error has been detected, a CPU
internal error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-02x
A non-critical error has been detected, a CPU
internal cache or cache controller error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-03x
A non-critical error has been detected, an
external cache parity or multi-bit ECC error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, see “
Solving undetermined
problems
” on page
194
.
A11-05x
A non-critical error has been detected, a
system bus time-out error.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
A11-06x
A non-critical error has been detected, a
time-out error waiting for an I/O device.
Check the management-module event log for an
entry around this time. If no entry is found, replace
the system-board and chassis assembly.
A11-50x
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use.
The system is operating with the potential for
an unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A11-510
Resource has been deconfigured and is no
longer in use due to a trend toward an
unrecoverable error.
1. Schedule maintenance; the system is operating in a
degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A11-540
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The system is
operating with the potential for an
unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A11-550
Recoverable errors on resource indicate a
trend toward an unrecoverable error.
However, the resource could not be
deconfigured and is still in use. The system is
operating with the potential for an
unrecoverable error.
1. If repair is not immediately available, reboot and the
resource will be deconfigured; operations can
continue in a degraded mode.
2. Check the management-module event log for an entry
around this time. If no entry is found, replace the
system-board and chassis assembly.
A12-00x
A non-critical error has been detected. Error
log analysis indicates an error detected by
the memory controller, but the failure could
not be isolated.
1. Check the management-module event log; if an error
was recorded by the system, see “
POST progress
codes (checkpoints)
” on page
71
.
2. If no entry is found, replace the system-board and
chassis assembly.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...