
32
Escala BL460 -
Problem Determination and Service Guide
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved. If an action solves the problem, then you can stop performing the remaining actions.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which
components are FRUs.
B200 xxxx
Error codes
Description Action
1143
A problem occurred during the migration of
a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the updates
if available.
1144
A problem occurred during the migration of
a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the updates
if available.
1148
A problem occurred during the migration of
a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the updates
if available.
1150
During the startup of a partition, a
partitioning configuration problem
occurred.
Go to “
Verifying the partition configuration
” on page
152
.
1151
A problem occurred during the migration of
a partition.
The migration of a partition did not
complete.
Check for server firmware updates; then, install the updates
if available.
1170
During the startup of a partition, a failure
occurred due to a validation error.
Go to “
Verifying the partition configuration
” on page
152
.
1225
A problem occurred during the startup of a
partition.
The partition attempted to start up prior to
the platform fully initializing. Restart the
partition after the platform has fully
completed and the platform is not in
standby mode.
Restart the partition.
1230
During the startup of a partition, a
partitioning configuration problem
occurred; the partition is lacking the
necessary resources to start up.
Go to “
Verifying the partition configuration
” on page
152
.
1260
A problem occurred during the startup of a
partition.
The partition could not start at the Timed
Power On setting because the partition was
not set to Normal.
Set the partition to Normal.
1265
The partition could not start up. An
operating system Main Storage Dump
startup was attempted with the startup side
on D-mode, which is not a valid operating
system startup scenario. The startup will be
halted. This SRC can occur when a D-mode
SLIC installation fails and attempts a Main
Storage Dump.
Correct the startup settings.
1266
The partition could not start up. You are
attempting to start up an operating system
that is not supported.
Install a supported operating system and restart the partition.
1280
A problem occurred during a partition
Main Storage Dump. A mainstore dump
startup did not complete due to a
configuration mismatch.
Go to “
Firmware problem isolation
” on page
185
.
1281
A partition memory error occurred. The
failed memory will no longer be used.
Restart the partition.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...