Chapter 2. Diagnostics
159
2.10.3
Intermittent problems
Identify intermittent problem symptoms and corrective actions.
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which components are
FRUs.
•
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Symptom Action
A problem occurs only
occasionally and is difficult to
diagnose.
1. Make sure that:
−
When the blade server is turned on, air is flowing from the rear of
the blade server at the blower grill. If there is no airflow, the blower
is not working.
This causes the blade server to overheat and shut down.
−
Ensure that the self configuring SCSI device (SCSD) bus and devices
are configured correctly.
2. Check the management-module event log for errors
2.10.4
Keyboard problems
Identify keyboard problem symptoms and what corrective actions to take.
•
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
•
See
Chapter 3
, “
Parts listing
,” on page
197
to determine which components are CRUs and which components are
FRUs.
•
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained
service technician.
Symptom Action
All or some keys on the
keyboard do not work.
1. Make sure that:
−
The keyboard/video select button LED on the front of the blade server is lit,
indicating that the blade server has ownership of the keyboard and video.
−
The keyboard cable is securely connected to the management module.
−
If you are using a PS/2 keyboard, the keyboard cable is connected to the
proper connector.
−
The blade server is using a supported Linux operating system that has loaded
completely and supports USB devices.
−
The blade server and the monitor are turned on.
2. Replace the keyboard.
3. Replace the management module on the Bull Blade Chassis - Enterprise. See the
Hardware Maintenance Manual and Troubleshooting Guide
or
Problem
Determination and Service Guide
for your Bull Blade Chassis - Enterprise.
Summary of Contents for Escala BL460
Page 1: ...Escala BL460 Problem Determination and Service Guide ESCALA Blade REFERENCE 86 A7 81FB 00...
Page 2: ......
Page 10: ......
Page 11: ...Preface vii Safety...
Page 13: ...Preface ix...
Page 14: ...x Escala BL460 Problem Determination and Service Guide...
Page 15: ...Preface xi...
Page 16: ...xii Escala BL460 Problem Determination and Service Guide...
Page 17: ...Preface xiii...
Page 19: ...Preface xv Guidelines for servicing electrical equipment...
Page 20: ......
Page 26: ...6 Escala BL460 Problem Determination and Service Guide Figure 1 1 DIMM connectors...
Page 220: ...200 Escala BL460 Problem Determination and Service Guide...
Page 260: ...240 Escala BL460 Problem Determination and Service Guide...
Page 265: ......
Page 266: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A7 81FB 00...