1-10 Notes on Using Your Server
FOR PROPER OPERATION
Observe the following notes for successful operation of the server. Use of the server ignoring the notes will cause malfunctions
or failures of the server.
Install the rack assembly in a place that meets requirements for successful operation. For details, see Chapter 3,
"Setting Up Your Server."
The server is intended for installation in a Restricted Access Location, mounted above a non-combustible material.
Make sure to power off the server before connecting or disconnecting cables between the server and peripheral
devices.
Verify that the access LED on the server is unlit before turning off the server or ejecting the floppy disk.
The server management logic on your system board monitors and logs system voltage changes. When plugging the
power cord to the system, you may experience 30 seconds delay from the time you press the POWER switch on the
front panel. This is normal system operation and is required by the server management logic.
Do not turn off the server until the POST (Power On Self-Test) completes. See Chapter 2 for details of POST.
When you have just turned off the server, wait at least 30 seconds before turning it back on.
When unplug the power cord(s) from the server, wait at least 30 seconds before re-pluging the power cord(s) to the
server.
Turn off the power and unplug the power cord from the outlet before relocating the server.
Clean the server on a regular basis. (See Chapter 7 for cleaning.) Regular cleaning proactively prevents various
failures of the server.
Lightning may cause a momentary voltage drop. To prevent this problem, it is recommended to use of an
uninterruptible power supply unit.
Check and adjust the system clock before the operation if any of the following conditions is applicable.
–
After carriage of device
–
After storage of device
–
After the device is entered into the pause state under the environmental condition enduring device operation
(temperature: 10°C - 35°C, humidity: 20% - 80%)
Check the system clock at the rough rate of once per month. When the system clock is installed in a system requiring
high time precision, it is recommended to use a time server (NTP server).
If the system clock is remarkably delayed or advanced as the passage of time in spite of adjustment, contact your
service representative to ask maintenance.
Summary of Contents for NovaScale R440 E2
Page 1: ...NovaScale R440 E2 User s Guide NOVASCALE REFERENCE 86 A1 46FB 00...
Page 2: ......
Page 32: ...1 16 Notes on Using Your Server...
Page 70: ...2 38 General Description...
Page 94: ...3 24 Setting Up Your Server This page is intentionally left blank...
Page 147: ...Configuring Your Server 4 53 Property of Physical Device in the Universal RAID Utility...
Page 272: ...5 74 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 308: ...7 12 Maintenance This page is intentionally left blank...
Page 408: ...9 54 Upgrading Your Server Screws...
Page 446: ...9 92 Upgrading Your Server This page is intentionally left blank...
Page 456: ......
Page 458: ...C 2 IRQ This page is intentionally left blank...
Page 490: ...D 32 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Page 494: ......
Page 544: ...G 2 Using a Client Computer with a CD Drive This page is intentionally left blank...
Page 548: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Page 551: ......
Page 552: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...