8-10 Troubleshooting
On-screen message
Action
RAID Adapter
FW Failed Validation!!!
Adapter needs to be reflashed.
Press any key to continue.
Contact your service representative to replace the
RAID controller.
Cache data was lost due to an unexpected
power-off or reboot during a write operation,
but the adapter has recovered. This could
be due to memory problems, bad battery, or
you may not have a battery installed.
Press any key to continue or 'C' to load the
configuration utility.
<When battery is not used>
Run WebBIOS or the Universal RAID Utility to
check the setting for cache mode. If forced
write-back is specified, change it to constant write
back or write through mode.
<When battery is used>
Check if the battery is connected properly.
If the same error persists, contact your service
representative to replace the RAID controller and
battery.
Entering the configuration utility in this state
will result in drive configuration changes.
Press 'Y' to continue loading the
configuration utility or please power off your
system and check your cables to ensure all
disks are present and reboot.
Contact your service representative to replace the
RAID controller.
Multibit ECC errors were detected on the
controller.
DIMM on the controller needs replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the
system and replace the DIMM module and
reboot. If you have replaced the DIMM
please press 'X' to continue.
Contact your service representative to replace the
RAID controller.
Multiple Single-bit ECC errors were
detected during the previous boot of the
controller. DIMM on the controller needs
replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the
system and replace the DIMM module and
reboot. If you have replaced the DIMM
please press 'X' to continue.
Contact your service representative to replace the
RAID controller.
Single-bit overflow ECC errors were
detected during the previous boot of the
controller. DIMM on the controller needs
replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the
system and replace the DIMM module and
reboot. If you have replaced the DIMM
please press 'X' to continue.
Contact your service representative to replace the
RAID controller.
Summary of Contents for NovaScale R440 E2
Page 1: ...NovaScale R440 E2 User s Guide NOVASCALE REFERENCE 86 A1 46FB 00...
Page 2: ......
Page 32: ...1 16 Notes on Using Your Server...
Page 70: ...2 38 General Description...
Page 94: ...3 24 Setting Up Your Server This page is intentionally left blank...
Page 147: ...Configuring Your Server 4 53 Property of Physical Device in the Universal RAID Utility...
Page 272: ...5 74 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 308: ...7 12 Maintenance This page is intentionally left blank...
Page 408: ...9 54 Upgrading Your Server Screws...
Page 446: ...9 92 Upgrading Your Server This page is intentionally left blank...
Page 456: ......
Page 458: ...C 2 IRQ This page is intentionally left blank...
Page 490: ...D 32 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Page 494: ......
Page 544: ...G 2 Using a Client Computer with a CD Drive This page is intentionally left blank...
Page 548: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Page 551: ......
Page 552: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...