Troubleshooting 8-23
A hard disk drive fails:
→
Contact your service representative.
Cannot enter standby:
→
If you use LSI Embedded MegaRAID
™
, system may not enter standby with heavy I/O.
Cannot enter Hibernation:
→
If you use LSI Embedded MegaRAID
™
, system may not enter hibernation with heavy I/O.
Physical device is not correctly displayed on Universal RAID Utility
→
If you use LSI Embedded MegaRAID
™
, a part of information on a physical device is not correctly displayed
on Universal RAID Utility.
It is not a problem.
Fail to install the OS:
Did you create virtual disks?
→
Create virtual disks by using WebBIOS.
Fail to start the OS:
Is the RAID controller inserted firmly straight into the PCI slot?
→
Install the RAID controller properly.
Is the RAID controller installed in the proper slot?
→
Check if the slot is appropriate for the RAID controller. If the same error persists, the RAID controller may
be faulty. Contact your service representative.
Are hard disk drives properly installed?
→
Install them properly.
Is the SAS cable connected correctly? (Check connection status with the server, hard disk drives, and additional
HDD cage.)
→
Connect the SAS cable properly.
If the same error persists, the hard disk drive may be faulty. Contact your service representative.
A hard disk drive fails:
→
Contact your service representative.
Rebuild fails:
Is the capacity of the hard disk drive to be rebuilt sufficient?
→
The hard disk drive to be rebuilt should have the same capacity of the failed hard disk drive.
Is RAID0 configured for virtual disk?
→
RAID0 has no data redundancy, therefore, Rebuild is disabled in the RAID0 configuration. Replace the failed
hard disk drive, then create the virtual disk again.
Check Consistency fails:
Is virtual disk "Degraded"?
→
Replace the failed hard disk drive with a new one, then perform Rebuild.
Summary of Contents for NovaScale R440 E2
Page 1: ...NovaScale R440 E2 User s Guide NOVASCALE REFERENCE 86 A1 46FB 00...
Page 2: ......
Page 32: ...1 16 Notes on Using Your Server...
Page 70: ...2 38 General Description...
Page 94: ...3 24 Setting Up Your Server This page is intentionally left blank...
Page 147: ...Configuring Your Server 4 53 Property of Physical Device in the Universal RAID Utility...
Page 272: ...5 74 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 308: ...7 12 Maintenance This page is intentionally left blank...
Page 408: ...9 54 Upgrading Your Server Screws...
Page 446: ...9 92 Upgrading Your Server This page is intentionally left blank...
Page 456: ......
Page 458: ...C 2 IRQ This page is intentionally left blank...
Page 490: ...D 32 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Page 494: ......
Page 544: ...G 2 Using a Client Computer with a CD Drive This page is intentionally left blank...
Page 548: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Page 551: ......
Page 552: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...