Troubleshooting 8-9
On-screen message
Action
Your VDs that are configured for write-back
are temporarily running in write-through
mode.
This is caused by the battery being charged,
missing, or bad.
Please allow battery to charge for 24 hours
before evaluating battery for replacement.
The following VDs are affected :XX
Press any key to continue.
<When battery is not used>
Ignore this message.
<When battery is used>
Run WebBIOS or the Universal RAID Utility to
check if battery is detected.
•
Battery is not detected:
– Check if battery is connected properly.
– Battery may be insufficiently charged. Halt the
system for 24 hours or longer and charge the
battery.
•
Battery is detected:
– Halt the system for 9 hours or longer and
charge the battery.
If the same error persists, contact your service
representative.
Invalid SAS Address present in MFC data.
Please program valid SAS Address, and
restart your system.
Contact your service representative.
Some configured disks have been removed
from your system, or are no longer
accessible. Please check your cables and
also ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
The following VDs have missing disks: xx
If you proceed (or load the configuration
utility), these VDs will be marked OFFLINE
and will be inaccessible.
Please check your cables and ensure all
disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
The following VDs are missing: xx
If you proceed (or load the configuration
utility), these VDs will be removed from your
configuration. If you wish to use them at a
later time, they will have to be imported. If
you believe these VDs should be present,
please power off your system and check
your cables to ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
All of the disks from your previous
configuration are gone. If this is an
unexpected message, then please power off
your system and check your cables to
ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
Check if the cables and hard disk drives are
connected properly. If the same error persists,
contact your service representative.
The cache contains dirty data, but some
VDs are missing or will go offline, so the
cached data can not be written to disk. If
this is an unexpected error,
then please power off your system and
check your cables to ensure all disks are
present. If you continue, the data in cache
will be permanently discarded.
Press 'X' to acknowledge and permanently
destroy the cached data.
Check if the cable, hard disk drives, and upgrade kit
are connected properly. If the same error persists,
contact your service representative.
NOTE: If you press
X
, the data in cache memory
will be lost.
Invalid memory configuration detected.
Please contact your system support.
System has halted.
Contact your service representative to replace the
RAID controller.
Summary of Contents for NovaScale R440 E2
Page 1: ...NovaScale R440 E2 User s Guide NOVASCALE REFERENCE 86 A1 46FB 00...
Page 2: ......
Page 32: ...1 16 Notes on Using Your Server...
Page 70: ...2 38 General Description...
Page 94: ...3 24 Setting Up Your Server This page is intentionally left blank...
Page 147: ...Configuring Your Server 4 53 Property of Physical Device in the Universal RAID Utility...
Page 272: ...5 74 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 308: ...7 12 Maintenance This page is intentionally left blank...
Page 408: ...9 54 Upgrading Your Server Screws...
Page 446: ...9 92 Upgrading Your Server This page is intentionally left blank...
Page 456: ......
Page 458: ...C 2 IRQ This page is intentionally left blank...
Page 490: ...D 32 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Page 494: ......
Page 544: ...G 2 Using a Client Computer with a CD Drive This page is intentionally left blank...
Page 548: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Page 551: ......
Page 552: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...