8-8 Troubleshooting
Messages displayed by RAID Controller during POST
On-screen message
Action
Memory/battery problems were detected.
The adapter has recovered, but cached
data was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Firmware version inconsistency was
detected.
The adapter has recovered, but cached
data was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Foreign configuration(s) found on adapter
Press any key to continue, or 'C' to load the
configuration utility.
Press
C
to run the utility to import or clear
configuration.
Previous configuration cleared or missing
Importing configuration created on
MM/DD hh:mm
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
An enclosure was found that contains both
SAS and SATA drives, but this controller
does not allow mixed drive types in a single
enclosure. Please correct the problem then
restart your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SAS drives were detected, but this
controller does not support SAS drives.
Please remove the SAS drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SATA drives were detected, but this
controller does not support SATA drives.
Please remove the SATA drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
Invalid SAS topology detected. Please
check your cable configurations, repair the
problem, and restart your system.
Check if the cable is connected properly. If the
same error persists, contact your service
representative.
The battery hardware is missing or
malfunctioning, or the battery is unplugged.
If you continue to boot the system, the
battery-backed cache will not function.
Please contact technical support for
assistance.
Press 'D' to disable this warning (if your
controller does not have a battery).
<When battery is not used>
Press
D
to hide this message.
<When battery is used>
Check if the battery is connected properly. If the
same error persists, contact your service
representative.
Summary of Contents for NovaScale R440 E2
Page 1: ...NovaScale R440 E2 User s Guide NOVASCALE REFERENCE 86 A1 46FB 00...
Page 2: ......
Page 32: ...1 16 Notes on Using Your Server...
Page 70: ...2 38 General Description...
Page 94: ...3 24 Setting Up Your Server This page is intentionally left blank...
Page 147: ...Configuring Your Server 4 53 Property of Physical Device in the Universal RAID Utility...
Page 272: ...5 74 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 308: ...7 12 Maintenance This page is intentionally left blank...
Page 408: ...9 54 Upgrading Your Server Screws...
Page 446: ...9 92 Upgrading Your Server This page is intentionally left blank...
Page 456: ......
Page 458: ...C 2 IRQ This page is intentionally left blank...
Page 490: ...D 32 Installing Windows Server 2008 4 Activate Windows The Windows activation is complete...
Page 494: ......
Page 544: ...G 2 Using a Client Computer with a CD Drive This page is intentionally left blank...
Page 548: ...H 4 Product Configuration Record Table This page is intentionally left blank...
Page 551: ......
Page 552: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 46FB 00...