136
System Configuration
Viewing Version Information
3 Optionally, type a descriptive name for your system to make it readily identifiable.
If there are more than one multiviewer in the same network environment, it is
important to assign each a unique system name, so that you can tell them apart (for
example, when using a remote control panel such as the Kaleido-RCP2 or RCP-200).
4 If your system requires a 50 Hz frame rate, to match the input signal data sampling rate,
in the absence of a reference signal, then select the corresponding check box.
5 Adjust the date and time settings, as required.
Clocks in your layouts will then display date and time in the applicable format.
6 Enter the appropriate IP information: frame or card IP addresses, network mask, and
default gateway.
By default, all network adapters are set to auto-negotiate. The connection speed and
duplex mode will be set automatically based on the corresponding port settings on the
associated switch. The current speed and link mode are displayed next to
Detected link
mode
, for every network adapter.
7 Should your network configuration require specific speed and duplex mode settings,
select the appropriate value from the
Configured link mode
list.
Notes
• Only lower-ASCII characters are allowed in the system name. Braces and
tilde are not allowed.
Summary of Contents for Grass Valley Kaleido-X
Page 22: ...22 Overview Functional Block Diagrams Simplified Signal Flow Diagram KX0 24Router...
Page 40: ...40 Installation Ventilation...
Page 100: ...100 IP Network Setup Network Considerations for a Multiviewer Cluster...
Page 123: ...123 Kaleido X 7RU Installation Service Manual 9 Click Finish A security warning appears...
Page 152: ...152 System Configuration Enabling Options...
Page 190: ...190 Maintenance Troubleshooting Disposal and Recycling Information...
Page 215: ...215 Kaleido X 7RU Installation Service Manual...