In the following example, the goal is to trigger a relay and light up a light.
To facilitate cabling of the GPI inputs and outputs, a terminal block adapter is available
separately (order code KXA-TBA-G). The GPI Terminal Block Adapter accommodates up to
24 terminal block connections using positive and negative terminal connections. Each
column on the terminal block has 6 positive and 6 negative terminal connections that
correspond to each pin position.
• For GPI outputs, terminals identified as N and P are used only.
• For GPI inputs, terminals identified as GND and P are used only.
CAUTION
In the example below, make sure your P and N connections are in the
proper polarity otherwise the GPI output will always be ON.
Microprocessor
Input
1.5k
Ω
24.9k
Ω
VCC
GPI #P
GND
GPI / Genlock Card
Buffer
Microprocessor
Output
200
Ω
VCC
GPI #P
GPI #N
GPI / Genlock Card
GPI configured as INPUT
GPI configured as OUTPUT
Microprocessor
Output
200
VCC
GPI #P
GPI #N
GPI / Genlock Card
Power
Supply B
Relay
Power
Supply A
Indicator Light
+
-
+
-
Summary of Contents for Grass Valley Kaleido-X
Page 22: ...22 Overview Functional Block Diagrams Simplified Signal Flow Diagram KX0 24Router...
Page 40: ...40 Installation Ventilation...
Page 100: ...100 IP Network Setup Network Considerations for a Multiviewer Cluster...
Page 123: ...123 Kaleido X 7RU Installation Service Manual 9 Click Finish A security warning appears...
Page 152: ...152 System Configuration Enabling Options...
Page 190: ...190 Maintenance Troubleshooting Disposal and Recycling Information...
Page 215: ...215 Kaleido X 7RU Installation Service Manual...