Multiviewer Cabling
Verifying that the Cards are Ready
Verifying that the Cards are Ready
To verify that the cards (modules) are ready:
• Check the status LEDs on each card installed in the Kaleido-X frame. Make sure that
none are indicating an error condition (see table below).
Photograph of a Kaleido-X (7RU) frame showing LED indicators on modules.
You can now proceed with the networking setup (see
Changing the Mosaic Output Resolution
To set a display’s output resolution from the monitor wall:
1 Connect a mouse to an output card’s USB connector. See
card's front edge USB connector
2 Right-click anywhere on the monitor wall, point to
Monitor wall
(if you clicked a
monitor), and then click
Display resolution
:
CPU LED Color Card Status Action Required
Solid green
Ready
None
Red
Fault
Verify that the card is securely seated in the proper slot in
the frame. If status remains unchanged, remove the card,
reseat it and then reboot.
Flashing green Rebooting
Wait for card to reboot before starting operations.