Multiple Rooms Are in the Same Enclosed Region
Warning
: Multiple rooms are in the same enclosed region. The correct area and perimeter will be assigned
to one room, and the others will display “Redundant Room.” You should separate the regions, delete the
extra rooms, or move them into different regions.
Issue
: This message displays when multiple rooms reside in the same region of the building model. In
schedules, Revit Architecture displays Redundant Room.
One of the rooms displays the correct area and perimeter. The others display Redundant Room so that the
space is not counted more than once in schedule totals. When a view displays the rooms using the Interior
Fill visibility setting, the rooms that report Redundant Room display in a darker color because the room
areas overlap.
Solution
: Do either of the following:
■
Use room-bounding model elements or room separation lines to divide the region into multiple rooms.
See
on page 979.
■
Remove the extra rooms. See
on page 1000.
Not Computed
Warning
: Not Computed
Issue
: This message displays for the Volume parameter in room tags and room schedules when you have
not enabled volume computation.
Because volume computation may affect Revit Architecture performance, enable it only when you want to
prepare and print schedules or other views that report volumes.
Solution
: To compute room volumes, click Home tab
➤
Room & Area panel drop-down
➤
Area and Volume
Computations. On the Area and Volume Computations dialog, under Volume Computations, select Areas
and Volumes.
Not Enclosed
Warning
: Room is not in a properly enclosed region.
Issue
: This message displays when a room is not properly enclosed by bounding elements or room separation
lines. For a room in a schedule, Revit Architecture displays Not enclosed.
Solution
: Add room separation lines, or turn on the Room Bounding parameter for elements, as appropriate.
on page 979.
Redundant Room
Warning
: Redundant room.
Solution
: See
Multiple Rooms Are in the Same Enclosed Region
on page 1006.
Room Is Very Short
Warning
: Room is very short. If this is not intended, change its Upper Limit and Offset.
Issue
: This message displays when you adjust the height of a room to be shorter than 4’ or 1200 mm.
1006 | Chapter 16 Rooms and Areas
Summary of Contents for 256B1-05A761-1301 - AutoCAD Revit Structure Suite 2010
Page 1: ...Revit Architecture 2010 User s Guide March 2009 ...
Page 4: ......
Page 42: ...xlii ...
Page 84: ...42 ...
Page 126: ...84 ...
Page 166: ...124 ...
Page 229: ...Schedule Field Formatting Calculating Totals Specifying Schedule Properties 187 ...
Page 230: ...Schedule with Grid Lines Schedule with Grid Lines and an Outline 188 Chapter 5 Project Views ...
Page 304: ...262 ...
Page 427: ...Defining the first scale vector Defining the second scale vector Resizing Graphically 385 ...
Page 454: ...Before painting applying material to stairs 412 Chapter 8 Editing Elements ...
Page 456: ...414 ...
Page 486: ...444 ...
Page 674: ...632 ...
Page 809: ...Curtain wall Curtain Grid Curtain Walls Curtain Grids and Mullions 767 ...
Page 994: ...952 ...
Page 1016: ...974 ...
Page 1204: ...1162 ...
Page 1290: ...1248 ...
Page 1318: ...1276 ...
Page 1372: ...1330 ...
Page 1382: ...1340 ...
Page 1462: ...1420 ...
Page 1492: ...1450 ...