5.10 Jitter Tolerance Setup Screen
5-89
5
R
em
ot
e C
on
trol
:SENSe:MEASure:BERCond:PATTern?
Response
<type>=<STRING RESPONSE DATA>
“file name”
Specify the file name according to “Appendix F” in the
MU183040B
Operation Manual.
Function
Queries the pattern to be used by ED for PAM4 Tolerance measurement.
Example
> :SENSe:MEASure:BERCond:PATTern?
< "PRQS10"
:SENSe:MEASure:BERCond:MANual:INTerface?
Response
<interface>=<CHARACTER RESPONSE DATA>
SING, DIF50, DIF100
Function
Queries the Data Input Condition of ED used for PAM4 Tolerance
measurement.
Example
> :SENSe:MEASure:BERCond:MANual:INTerface?
< "SING"
:SENSe:MEASure:BERCond:MANual:DATA <thre>,<volt>
Parameter
<thre>=<CHARACTER PROGRAM DATA>
UPPer
Upper Eye threshold
MIDDle
Middle Eye threshold
LOWer
Lower Eye threshold
<volt>=<DECIMAL NUMERIC PROGRAM DATA>
–3.500 to 3.300
–3.500 to 3.300 V/0.001 V step
Function
Sets the eye threshold for the Data Input of ED used for PAM4 Tolerance
measurement.
Example
To set the Upper Eye threshold of Data Input to 0.100 V:
> :SENSe:MEASure:BERCond:MANual:DATA UPPer,0.100