5.10 Jitter Tolerance Setup Screen
5-75
5
R
em
ot
e C
on
tro
l
:SENSe:JITTer:TABLe:ADD <freq>,<mask>,<upperlimit><lowerlimit>
Parameter
<freq>=<DECIMAL NUMERIC PROGRAM DATA>
10 to 250000000
Modulation frequency registered in the Jitter
Tolerance Table
<mask>=<DECIMAL NUMERIC PROGRAM DATA>
0 to 2000
Mask value registered in the Jitter Tolerance
Table
<upperlimit>=<DECIMAL NUMERIC PROGRAM DATA>
0 to 2000
Upper Limit value registered in the Jitter
Tolerance Table
<lowerlimit>=<DECIMAL NUMERIC PROGRAM DATA>
0 to 2000
Lower Limit value registered in the Jitter
Tolerance Table
Function
Adds modulation frequencies to be measured to the Jitter Tolerance
measurement.
Example
> :SENSe:JITTer:TABLe:ADD 100000000,0.100,0.5,0.1
Note:
In accordance with the SJ specifications in Section 1.3 of
MU181500B Jitter Modulation Source Instruction Manual.
:SENSe:JITTer:TABLe:DELete <number>
Parameter
<number>=<DECIMAL NUMERIC PROGRAM DATA>
1 to 50
1 to 50/1step
Function
Deletes those items on the Jitter Tolerance Table specified by number.
Example
> :SENSe:JITTer:TABLe:DELete 1
:SENSe:JITTer:TABLe:ADELete
Parameter
None
Function
Deletes all elements on the Jitter Tolerance Table.
Example
> :SENSe:JITTer:TABLe:ADELete
Summary of Contents for MX183000A
Page 12: ...xii ...
Page 16: ...IV ...
Page 20: ...Chapter 1 Outline 1 4 Figure 1 1 3 Jitter Tolerance Graph Screen ...
Page 54: ...Chapter 3 Connecting Equipment 3 16 ...
Page 136: ...Chapter 5 Remote Control 5 30 Figure 5 8 2 Sequence Screen BER Measurement 10 8 9 11 ...
Page 206: ...Chapter 5 Remote Control 5 100 ...
Page 218: ...Appendix A Specifications A 12 ...
Page 226: ...Appendix B Default Settings B 8 ...