Chapter 5 Remote Control
5-56
Table 5.9-1 Sequence Screen Setup Commands
No.
Setting Item
Command
[1]
Sequence Start
:LTRaining:SEQuence:STARt
Sequence Stop
:LTRaining:SEQuence:STOP
Sequence State
:LTRaining:SEQuence:STATe?
[2]
Not Wait For The LFPS signal :LTRaining:SEQuence:NWAit:LFPS
:LTRaining:SEQuence:NWAit:LFPS?
[3]
Specification
:LTRaining:SEQuence:SPECification
:LTRaining:SEQuence:SPECification?
[4]
Transmit Test Pattern
:LTRaining:SEQuence:TEST:PATTern:TRANsmit
Stop Test Pattern
:LTRaining:SEQuence:TEST:PATTern:STOP
[5]
Test pattern
:SOURce:PATTern:TYPE
:SOURce:PATTern:TYPE?
[6]
Test pattern
:LTRaining:SEQuence:TEST:PATTern
:LTRaining:SEQuence:TEST:PATTern?
[7]
Add Single Bit Error
:LTRaining:SEQuence:TEST:PATTern:EADDition
[8]
Reset
:LTRaining:SEQuence:INITialize
[9]
Sequence
:LTRaining:SEQuence:DESign:GEN1
:LTRaining:SEQuence:DESign:GEN1?
:LTRaining:SEQuence:DESign:GEN2
:LTRaining:SEQuence:DESign:GEN2?
:LTRaining:SEQuence:STARt
Parameter
None
Function
Changes PPG to the wait status for receiving LFPS from DUT.
The link training sequence for looping back DUT is transmitted after
receiving LFPS.
After the transmission, the pattern selected at Test Pattern is sent
continuously.
Example
> :LTRaining:SEQuence:STARt
:LTRaining:SEQuence:STOP
Parameter
None
Function
Stops transmitting link training sequence and test pattern and sets to
Electrical Idle.
Example
> :LTRaining:SEQuence:STOP
Summary of Contents for MX183000A
Page 12: ...xii ...
Page 16: ...IV ...
Page 20: ...Chapter 1 Outline 1 4 Figure 1 1 3 Jitter Tolerance Graph Screen ...
Page 54: ...Chapter 3 Connecting Equipment 3 16 ...
Page 136: ...Chapter 5 Remote Control 5 30 Figure 5 8 2 Sequence Screen BER Measurement 10 8 9 11 ...
Page 206: ...Chapter 5 Remote Control 5 100 ...
Page 218: ...Appendix A Specifications A 12 ...
Page 226: ...Appendix B Default Settings B 8 ...