The scan interval ranges from 15 seconds to 1 month.
File Name Prefix: Users can configure the file name prefix for the Comtrade file that is sent
to the server.
Post Method: From the drop down menu select either FTP or HTTP/HTTPs
For FTP configure the following:
FTP URL: Enter the URL for the FTP server. The URL needs to begin with the prefix ftp://
FTP Port: Enter the port number the server will be listening on
FTP Username: Enter the username required to log into the FTP server
FTP Password: Enter the password required to log into the FTP server
For HTTP/HTTPs configure the following:
HTTP/HTTPS URL: Enter the URL for the HTTP/HTTPS server. The URL needs to begin with
the prefix http:// or (https://)
HTTP/HTTPS Port: Enter the port number the server will be listening on
HTTP/HTTPS Meter ID: Enter a name or description for the meter to be identified on the
server
NOTE: The 'Test Waveform Post' button should only be utilized after clicking the 'Save'
button otherwise a fail response will be observed. If the test post fails users can view the
test post details by clicking on the 'Details' option from the test post screen.
Similar to the Post Channel function discussed earlier, in the case when there is no connec-
tion to the server the AXM-WEB2 will store the posts and send it out after the connection is
restored. A maximum of 3000 files will be buffered on module. The 'Clear Waveform Post
Channel Logs' button will allow users to clear the buffered waveform files on meter.
There is no interval setting for sending the waveform data using the waveform post, the
data will post directly to the FTP/HTTP server when a power quality event has occurred.
NOTE: All waveform capture settings must be configured on the Acuview software.