www.accuenergy.com
V: 1.10 Revised: January 2020
93
Chapter 10: Web Interface Readings and Parameter Settings
Waveform Post
The AXM-WEB2 supports the HTTP and FTP Post functions to send the meters waveform data
from the meter to a HTTP/FTP server. The AXM-WEB2 can post the Comtrade (.cfg and .dat) files
to either an HTTP or FTP servers using the Waveform Post. The settings for the Waveform Post
can be found by clicking on the 'Settings' tab and selecting 'Communications', from the Com-
munications page click on the 'Waveform Post' tab.
NOTE: This function is only available on Acuvim IIW models which support the Waveform Cap-
ture Function, all other models will not have this feature available.
Waveform Post Enable: Select Enable to enable the waveform post and configure the settings
further.
Scan Interval: Users can configure a scan interval where the AXM-WEB2 module scans at the
Acuvim II meter to check whether there are any power quality events that occurred during the
selected scan interval. For example if the scan interval is set for 15 minutes the module will
scan for all the power quality events that occurred within 15 minutes and post it to the server.