![ABB Relion REC615 Technical Manual Download Page 854](http://html.mh-extra.com/html/abb/relion-rec615/relion-rec615_technical-manual_3045253854.webp)
14.7
Signal output with high make and carry
Table 757: Signal output with high make and carry
Description
Value
1
Rated voltage
250 V AC/DC
Continuous contact carry
5 A
Make and carry for 3.0 s
15 A
Make and carry for 0.5 s
30 A
Breaking capacity when the control-circuit
time constant L/R <40 ms
1 A/0.25 A/0.15 A
Minimum contact load
100 mA at 24 V AC/DC
14.8
Signal outputs and IRF output
Table 758: Signal outputs and IRF output
Description
Value
1
Rated voltage
250 V AC/DC
Continuous contact carry
5 A
Make and carry for 3.0 s
10 A
Make and carry 0.5 s
15 A
Breaking capacity when the control-circuit
time constant L/R <40 ms, at 48/110/220 V
DC
1 A/0.25 A/0.15 A
Minimum contact load
10 mA at 5 V AC/DC
1
X100: SO1
X110: SO1, SO2
X130: SO1, SO2 when REC615 is equipped with BIO0006
1
X100: IRF,SO2
Technical data
1MRS758755 C
854
REC615 & RER615
Technical Manual