CONFIGURING A DWELL TIMER ZONE
Steps:
1).
To configure a VCA Zone with Dwell Timer Alarm, navigate to the
Setup (Advanced) Tab > VCA
> Zones and Rules
settings page.
2).
Right-click in the video preview area and select
Zone/Line>Create Zone
.
3).
Draw the zone as desired by clicking and dragging each corner until a satisfactory shape and
position is achieved.
4).
Assign a
Name
and
Color
to the zone.
Figure 4-11:
Configuring a VCA Dwell Timer Zone
5).
Enable the
Dwell
rule.
6).
Set an appropriate dwell
Threshold
.
5 seconds is used in the above example.
7).
Click
Apply
to save the new zone settings.
An analytics dwell event(alarm) will now trigger whenever an object has spent more than 5 seconds in