4).
Configure your conditional trigger clause as desired. When you have configured the clause, the
trigger actions must also be selected. The trigger action is simply the resulting action of the
logical rule being triggered.
A list of available trigger actions is described below:
Logical Rule - Action
Description
[generateevents]
Select this action to generate an event whenever the logical rule is
triggered.
[incrementcounter]
Select this action to increment a specified VCA counter whenever
the logical rule is triggered.
[learnscene]
Select this action to have the camera perform scene learning
whenever the logical rule is triggered.
[resetcounter]
Select this action to reset a specified VCA counter whenever the
logical rule is triggered.
5).
Once you have configured both a conditional clause and a trigger action, click
OK
to save the
new logical rule.
CALIBRATION SETTINGS
Steps:
1).
Opening the
Setup Tab>VCA
drop-down menu and clicking the
Calibration
link will open the
network
DDNS
settings page.
Figure 7-72
: Setup Tab –VCA Menu –Calibration Settings
2).
The VCA calibration process includes configuring the correct camera angle and field of view, as
well as the delineation of anticipated object
(people, car, etc…)
size. Proper calibration of the
camera is required to ensure accurate analytics counts and tracking.