VIGIL Software v8.8 User Manual |
VISIX V-Series All-in-One Cameras
10225 Westmoor Drive, Suite 300, Westminster, CO 80021 | www.3xlogic.com | (877) 3XLOGIC
19
4.3
Configure a Video Analytics (VCA) Rule (Analytics License Required)
ENABLING VCA
Before configuring any analytics rules, VCA (video content analysis) must first be enabled on your All-in-
One camera. An All-in-One Analytics license
is required
to configure and utilize VCA analytics rules on
VISIX All-in-One cameras. To enable VCA:
Steps:
1).
Navigate to the
Setup (Advanced) Tab > VCA > Enable/ Disable
settings page.
2).
Check off
Enable
under the VCA Configuration section.
Figure 4-7:
Enabling VCA Analytics
After enabling VCA, several other configuration options will be deployed.
3).
Under the
VCA Features
section, select active analytics type. For the purposes of this example,
both
Object Tracking
and
Counting Line
will be enabled.
4).
Under the
Tracking Mode
section, select the analytics tracking mode. In this example, the
People
tracking mode is selected (People tracking requires an Advanced analytics license. If
using
Surveillance
tracking mode, the steps in this example are still accurate.)
5).
Click
Apply
to save the new settings.
VCA ANALYTICS CALIBRATION
Another preliminary step before configuring VCA analytics rules is the need to calibrate the cameras for
accurate analytics object recognition and tracking.
The calibration process includes configuring the correct camera angle and field of view, as well as the
delineation of anticipated object (people, car, etc…) size. Proper calibration of the camera is required to
ensure accurate analytics counts and tracking. To begin calibration:
Steps:
1).
Navigate to the
Setup (Advanced) Tab > VCA > Calibration
settings page.