12.5
Emergency evacuation by opening the brakes
Emergency evacuation through manually or electrically opening the motor brakes until the cabin has
reached the next
fl
oor in the direction of the pulling load.
Danger!
If an emergency evacuation is carried out by opening the brakes, the motor windings must be
short-circuited for the evacuation to prevent an uncontrolled acceleration of the elevator. The
short-circuit generates a speed-dependent braking torque, suf
fi
cient in most cases to limit the
elevator speed to a safe level.
CAUTION!
Caution!
Short-circuiting the motor windings must be authorized by the motor manufacturer. This is tested and
guaranteed in Ziehl-Abegg motors.
12.5.1
Monitor function
Monitoring of evacuation direction and evacuation speed during the evacuation process.
The monitoring function will be activated by a digital input.
Control system
|
-
"
f_I08
41:Monitor
|
-
"
41:Monitor
Function of I08
Con
fi
gure the digital input in the
Control system
menu to the function
41:Mon-
itor
.
Activating of the monitoring function
•
Switch off the frequency inverter
•
activate the digital input with the "Monitoring" function
•
Switch on the frequency inverter
•
Monitoring function is active
Elevator-Monitor
Speed: 0.2m/s
Direction: up
▲
Distance: +1.24m
Elevator-Monitor
Speed:
Display of the actual evacuation speed
Direction:
Display of the actual evacuation direction
▲
Evacuation speed < Limit V_G1
▲▲
Evacuation speed > Limit V_G1
Distance:
Display of the evacuation distance past
Information
During activated Monitoring-Function, all further functions of the frequency inverter are
locked!
Original operating instructions
ZETADYN 3C
Emergency evacuation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
131/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...