5.21.4.1
Technical data brake contactors
K3
(ac side)
K4
(dc side)
Operating voltage
88...121 VAC
220...240 VAC
88...121 VDC
176...242 VDC
Power consumption
≤
5 W
≤
5 W
max. 8 W
max. 8 W
Opening time* 3C011 to 3C032
40 ms
40 ms
13 ms
13 ms
Opening time* 3C040 to 3C074
40 ms
40 ms
19 ms
19 ms
*
Period between the deenergization of the solenoid and disconnection of the pole contacts.
The integrated brake triggering is build for connecting drives with two brake circuits, with the following
technical data:
Input voltage at overexcitement (U~)
100 - 250 V~
Output voltage at overexcitement (U~)
0,45 x U~
Input voltage with recti
fi
er (U~)
max. 400 V~
Output voltage with recti
fi
er (U~)
0,45 x U~
Holding current (both brake circuits)
2 A
5.21.4.2
Emergency power suply
Information
If no voltage is available for bleeding the brake due to a fault in the voltage supply, an external voltage
can be connected directly to terminal X3:1/2 and X3:3/4 for manual bleeding of the brakes. This
ensures fast rescue of trapped passengers in the event of a fault.
Original operating instructions
ZETADYN 3C
Electrical installation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
46/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...