5.13.2.1
Connection PWM
X-BC
PWM
24V
BC
(1)
(2)
(3)
(4)
Kx
Connection of the digital output PWM
Kx
Control relay
()
terminal designation of connector
5.13.3
Technical data
X-OUT
X-BC (PWM)
Short-circuit-proof
no*
Min. switching capacity
5 mA / 12 VDC
5 mA / 24 VDC
Max. switching capacity
2 A / 250 VAC
5 mA / 24 VDC
Cable cross section
max. 2,5 mm
²
max. 1,5 mm
²
CAUTION!
Caution!
* In order to protect the relay contacts, switched inductivities must be provided with an external
suppressor circuit (suppressor diode, RC element).
5.13.4
Terminal assignment X-OUT
The output assignments can be con
fi
gured. The con
fi
guration can be implemented by:
•
Presetting the used control system (assignment corresponding to the control requirements)
•
Free con
fi
guration
Implement con
fi
guration of the digital outputs in the
Control system\CONFIG
menu.
Please refer to the "Parameter list/Control menu" chapter for a description of the individual parameters
The output assignments dependent on the con
fi
guration:
Con
fi
gura-
tion
Outputs
O11 - O14
O21 - O24
O31 -O34
O41 - O44
PWM
00:Free
Fault*
MB_Brake*
MotContact*
V < V_G1*
AUS*
01:ZA_IO
Err
MB_Brake
MotContact
V < V_G1
AUS
03:BP_IO
Err
MB_Brake
MotContact
V < V_G1
AUS*
08:KN_IO
Err
MB_Brake
MotContact
V < V_G1
AUS*
11:NL_IO
Err
MB_Brake
MotContact
V < V_G1
AUS*
13:SS_IO
Err
MB_Brake
MotContact
V < V_G1
AUS*
15:ZA_BIN
Err
MB_Brake
MotContact
V < V_G1
AUS*
16:WL_IO
Err
MB_Brake
MotContact
V < V_G1
AUS*
21:ST_IO
Err
MB_Brake
MotContact
V < V_G1
AUS*
24:CSILVA
Err
MB_Brake
MotContact
V < V_G1
AUS*
25:S+S
MotContact
MB_Brake
V=O
Err
AUS*
27:MAS_BIN
Err
MB_Brake
MotContact
Off*
AUS*
30:KS_IO
Err
MB_Brake
MotContact
V < V_G1
AUS*
31:KL_IO
fault
MB_Brake
MotContact
EVAC.DIR
AUS*
32:
S_SMART
Err
MB_Brake
MotContact
SD
AUS*
*
The function of the outputs can be changed
Original operating instructions
ZETADYN 3C
Electrical installation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
33/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...