15.11
Travel direction counter
Information
The travel direction counter is a down counter which is counting the allowed travel direction changes
with coated ropes. With the travel direction counter the frequency inverter shows an accurately timed
info text when a rope change is necessary.
15.11.1
Parameters for the travel direction counter
For the travel direction counter there are the following parameters, available in the menu
Statistic
.
In order to be able to use all parameters, the password
TD_PWN
must be assigned
fi
rst.
Parameter
Description
Value range
Factory setting
TD_PWN
New password
A number between 0 and 9999 can be used as a
password
0 ... 9999
0
TD_PWC
Displays the password in coded form. If you lose the
password, please contact the manufacturer.
nicht einstellbar
21689
TD_PW
Enter password.
0 ... 9999
0 = no password
0
TD_CNT
Initial value of the down counter
0.00 ... 10.00 M
0.00
The current counter readings and the start value of the direction change counter are also available in
the
INFO menu
on
page 20
.
15.11.2
Parametrization of the counter
For using the travel direction counter, the following parameters have to be adjusted.
Statistics
|
-
"
TD_PWN
0
|
-
"
0
*New password
Assign new password with the parameter
"TD_PWN"
in the menu
"Statistic"
.
If there is already a password existing, you have to enter it to "TD_PW" before it
can be replaced by a new password.
Statistics
TD_PWN 0
->TD_PWC 21689
*Encrypted password
The coded password is shown with the parameter
"TD_PWC"
in the menu
"Statistic"
.
With the coded password the ZIEHL-ABEGG SE can decode the original pass-
word.
For example if the owner has forgotten it.
Statistics
|
-
"
TD_PW
0
|
-
"
0
*Password entry
Before you can change TD_CNT you have to enter the password to the parame-
ter
"TD_PW"
in the menu
"Statistic"
.
Statistics
|
-
"
TD_CNT 0
M
|
-
"
0
*Down counter start value
Enter the maximum allowed travel directions with the parameter
"TD_CNT"
in the
menu
"Statistic"
.
CAUTION!
Caution!
When replacing the ZETADYN 3 the actual value of the down counter "TD_CNT" must be
transferred to the new ZETADYN 3!
Original operating instructions
ZETADYN 3C
Special functions
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
184/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...