Error no.
Error text
Error cause
M S
570
PFU Alarm
Error:
Monitor contact of the power feedback unit opens during operation of
the ZETADYN
Remedy:
Check connection of the feedback unit function monitor,
Check function monitor of power feedback unit,
Check the function of the power feedback unit
The error is automatically acknowledged when the monitor contact of the
power feedback unit reconnects.
●
571
PFU:Stdby remains in
place
Error:
PFU is not yet active 1 s after start of travel
●
575
MOT: Temp. -Alarm
Error:
Motor temperature monitor triggered during the trip (error evaluation
only if error no. 575 is entered in the mask function)
Remedy:
Check the parameter in the "Motor name plate" menu,
check the motor's duty cycle,
check the motor for winding short,
check the encoder,
Check the brake function
●
●
582
BR:T2 too small
Error:
Brake does not open within time T2 (only active if brake monitor is
switched on)
Remedy:
Check the brake triggering,
check the brake opening time,
check the con
fi
gured brake opening time "T_2" in the "Start" menu and
increase if necessary
●
583
BR: Fault Travel
Error:
Brake monitoring contacts triggered during travel
Remedy:
Check the brake triggering,
check the monitoring contacts,
check the power supply of the brakes
Information:
•
Negated function: If entered in the mask, the error leads to immediate stop of
travel
•
Error does not lead to blocking of the ZETADYN with parameter LOCK-
BR="ON"
●
●
584
BR: Fault Travel
Error:
Brake monitoring contacts triggered during travel
Fault message at end of travel with additional information = 0:
Brake monitor contacts have switched during travel but the brake was not
closed
Fault message without immediate interruption of travel and additional informa-
tion
≠
0:
Brake was closed during travel
Additional information:
Indicates consequential fault
Remedy:
Check the brake triggering,
check the monitoring contacts,
check the power supply of the brakes
Information:
Error does not lead to blocking of the ZETADYN with parameter LOCK-
BR="ON"
●
●
585
BR: T5 too small
Error:
Brake does not close within time T5 (only active if brake monitor is
switched on)
Remedy:
Check the brake triggering,
check the brake closing time,
check the con
fi
gured brake opening time "T_5" in the "Stop" menu and
increase if necessary
●
586
BR: Stop-Error
Fault:
Monitoring contact of the brake brie
fl
y signals "Brake closed and then
"Brake open" again longer as the time T5 (only active with the brake monitor
switched on)
Remedy:
Check the brake triggering,
check the brake closing time,
check the con
fi
gured brake opening time "T_5" in the "Stop" menu and
increase if necessary
Original operating instructions
ZETADYN 3C
Error diagnosis
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
144/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...