Information
The paramters which are necessary for the Open-Loop-operation are only displayd with the paramter
C_MOD=U/f
. The parameters are described in the chapter Open-Loop-operation".
10.14
Parameter set 2 menu
A second set of parameters can be stored in the inverter. This can be used for:
•
Emergency evacuation
•
Normal travel with changed parameter values
•
Parameter back-up
Parameter
Description
Value range
Factory set-
ting
F_PAR2
Function allocation of parameter set 2
Locked:
2.nd parameter set is blocked
2.ndParameter set:
Activates the 2.nd parameter set
EVAC 3:
Emergency evacuation with evacuation module EVAC
3
EVA. 3*AC:
Emergency evacuation through three-phase current
emergency-generator
EVA. 1*AC:
Emergency evacuation through UPS
UPS:
Emergency evacuation through UPS (with decreased
power)
Locked
2nd parameter set
EVAC 3
EVA. 3*AC
EVA. 1*AC
UPS
Locked
U_ACCU
Accu nominal voltage
Con
fi
guring the rated voltage of the rechargeable battery during
evacuation with evacuation unit EVAC 3 ("f_PARA2=EVAC 3B",
see "Emergency evacuation" chapter)
60 ... 565 V
120
P_UPS
Max. Load UPS
Con
fi
guring the available power of the UPS during evacuation
with UPS ("f_PARA2=UPS", see "Emergency evacuation" chap-
ter)
0.0 ... 70.0 kW
1.0
RS_UPS
Stator resistor
Enter the resistor of the stator of themotor with "f_PARA2=UPS"
0.0 ... 9.99 Ohm
1.00
STOP
Stop function to improve the positioning accuracy in the evacua-
tion mode "f_PARA2=UPS"
ON:
- Brake is closed when the switch point for V_1 is closed.
- Brake is closed when the residual path con
fi
gured in S_STOP
has been reached (only for DCP02/04
Off:
Stop function deactivated
On
Off
Off
Copy
Copy parameter set
OFF:
Function deactivated
PARA1->2:
copies the data from 1st parameter set into the 2nd
parameter set
Off
Para 1->2
Off
Original operating instructions
ZETADYN 3C
Parameter list
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
91/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...