8
Start-up
Danger!
Defective connections can cause the motor to start unexpectedly or lead to uncontrolled motor
movements.
Reversed connections cause the motor to rotate in the wrong direction. That can cause serious
machine damage.
CAUTION!
Caution!
Incorrectly wired connections can destroy the electrical / electronic components.
Electrostatic discharges can be hazardous to the electronic components and lead to errors in the
software.
You must comply with the following points to prevent machine damage or life-threatening injuries
when commissioning the machine:
•
Only suitably quali
fi
ed personnel are to be entrusted with the commissioning of the device. They
must comply with the safety instructions.
•
Before starting work, make sure all tools and external parts have been removed from the machine.
•
Activate all safeguards and the emergency-off switches before commissioning.
•
Make sure no unauthorized persons are in the machine working area and that no other persons can
be endangered when the installation is started up.
•
inspect the electrical connections before the
fi
rst start
•
Pay special attention to the protective measures (e.g. grounding, ...) for the electrostatically
endangered components.
•
Also read the chapter "General Safety Instructions".
Information
This commissioning assumes the factory settings for the digital inputs and outputs, encoder inputs and
monitoring contacts have not been modi
fi
ed!
Requirements for error-free commissioning:
•
Mains line is connected
•
Motor is connected
•
Brake chopper or Brake resistor are connected
•
Controller and monitoring inputs are connected
•
Encoder is connected
Information
Startup takes place in the basic level. To go to the advanced level, press the key long (see chapter
"Opeation and Parameterisation / The different operating levels") or go to the
Startup
menu and set
the
USR_LEV = Advanced
parameter.
Start-up
|
-
"
USR_LEV Advanced
|
-
"
Advanced
User level
8.1
Precon
fi
gured inverter
Inverters preprogrammed by ZIEHL-ABEGG are provided with the following information plate on the
faceplate
Information
Preset parameters
Preset paramters
In these units, the parameters are factory preset, based on customer speci
fi
c information. Entering
parameters is no longer necessary but the parameters must be checked before commissioning!
Original operating instructions
ZETADYN 3C
Start-up
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
57/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...