12
Emergency evacuation
12.1
Evacuation with 1-phase mains supply 230V AC
Due to the low power requirements of a synchronous drive, it is possible to carry out an evacuation trip
in the motoric and generatoric direction.
Due to the high level of magnetization current, emergency evacuation with a single-phase mains
supply with asynchronous motors does not make sense.
Information - Characteristics of evacuation with single-phase mains supply:
•
Evacuation in motoric and generatoric direction
•
Load-independent starts
•
Load-independent stopping
•
Flush stopping
If there is a mains failure, the mains supply must provide the following voltage to the inverter:
•
230 VAC to feed L1 and L2
The frequency inverter analyses the load ratio between the car and the counterweight during every
start.
The control system starts the evacuation trip by activating:
•
Controller enable
•
Direction default
•
Speed default
Size of the voltage supply
The required performance consists of the following:
Electronic frequency inverter power consumption
+ Control systempower consumption
+ Electromechanical brakes power consumption
+ Other consumers (car light,
…
) power consumption
+ Motor power consumption during motoric operation with suf
fi
cient power
(ask motor manufacturer)
=
Real power [W]
Information
The shaft ef
fi
ciency has a decisive in
fl
uence on the required power of the single-phase mains supply.
Original operating instructions
ZETADYN 3C
Emergency evacuation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
124/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...