Error no.
Error text
Error cause
M S
207
Input PFU_BR miss.
Fault:
When using a feedback unit in connection with a brake resistor the
temperature monitor of the brake resistor is not programmed
Remedy:
Parameterise digital input (preferably X_BR4) in the "Control" menu
to the "PFU_BR" function
●
208
DELAY active
Error:
Emergency stop was done by deactivating of the input with the function
"/DELAY"
At travel start, the input with the function "/DELAY" is not active
Remedy:
Check the triggering of the input with the function "/DELAY"
210
Wrong ENC_TYP
Error:
Encoder type and motor type do not match
Remedy:
Enter the correct encoder type in the "Encoder & BC"menu
●
●
211
No binary encoder
Error:
With theb encoder types TTL-sine wave or EnDat/SSi no binary resolu-
tion was enterd
Remedy:
Enter a binary resolution (e.g. 512, 1024 or 2048)
213
ZR_EN /ZR_RDY miss-
ing
Error:
"ZR_RDY" or "ZR_EN" was not con
fi
gured
Remedy:
Set digital input to "ZR_RDY" or set digital output to "ZR_EN"
220
Error: SM data
Error:
While operating synchronous motors, the values for the rated speed (n)
and the rated frequency (f) do not match in the "Motor name plate" menu
Remedy:
Enter the correct data for rated speed and rated frequency in the
"Motor name plate" menu
●
●
221
Error: ASM data
Error:
While operating asynchronous motors, the values for the rated speed
(n) and the rated frequency (f) do not match in the "Motor name plate" menu
Remedy:
Enter the correct data for rated speed and rated frequency in the
"Motor name plate" menu
●
●
231
V_G1 > 150% V*
Error:
the limit value con
fi
gured for V_G1 is too large
Remedy:
Con
fi
gure the limit value V_G1 to max 150% V* in the "Control
system" menu
232
V_G2 > 150% V*
Error:
the limit value con
fi
gured for V_G2 is too large
Remedy:
Con
fi
gure the limit value V_G2 to max 150% V* in the "Control
system" menu
233
V_G3 > 150% V*
Error:
the limit value con
fi
gured for V_G3 is too large
Remedy:
Con
fi
gure the limit value V_G3 to max 150% V* in the "Control
system" menu
240
ZR:Not RDY
Error:
At start of travel, no signal present at the digital input set to "ZR_RDY"
Remedy:
Check wiring
Use the ZArec display to check for an error at the ZArec
Exit ZArec con
fi
guration level
270
Cable change warning
Error:
Information travel direction change counter
Replacement of the cables in about 1 year
280
S31 too long
Error:
the calculated deceleration path S31 is too long
Remedy:
in the "Decelerate" menu, increase the deceleration "A_NEG" or
reduce the round offs "R_NEG1" and "R_NEG2
●
285
Installation:V*=0
Error:
V* in the "Installation data" menu has not been assigned
Remedy:
Check the parameter in the "Installation" menu
287
V1 . . . V7 > V*!
Error:
One of the travelling speeds V_1 ... V_7 entered is larger than the
entered rated speed V*
Remedy:
Con
fi
gure speeds V_1
…
V_7 in the "Travel" menu to
≤
V*
288
V_3 > V*
Error:
The traveling speed V_3 entered is larger than the entered rated speed
V*
Remedy:
Set speed "V_3" in the "Travel" menu to
≤
V
●
●
289
V_1 < V_2 < V_3!
Error:
Speeds in the "Travellingl" menu are incorrectly set
Remedy:
In the "Travel" menu, make sure that V_1 < V_2 and V_2 <V_3
●
●
290
ParaSet2 empty!
Error:
Activated parameter set 2 does not contain any data
Remedy:
In the "Parameter set 2" menu, copy the the data from parameter set
1 to parameter set 2
●
Original operating instructions
ZETADYN 3C
Error diagnosis
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
137/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...