![ZIEHL-ABEGG ZETADYN 3C Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/ziehl-abegg/zetadyn-3c/zetadyn-3c_original-operating-instructions_3741629040.webp)
5.19.2
Connection X-EXT
X-EXT
24V
_EX
GND
_EX
+24V
0V
(1)
(2)
1
Connection external power supply
1
external power supply
()
terminal designation of connector
5.20
Motor contactors
The installed motor contactors are selected depending on the motor type and the corresponding
motor data. The contacts of the motor contactors are forced in accordance with DIN EN 81-1.
When operating asynchronous motors, two main contactors with 3 main contacts (3x NO) are used for
the motor connection and 3 auxiliary contacts (2x NO and 1x NC) each for the external contactor
monitoring.
When operating synchronous motors, one main contactor with 3 main contacts (3x NO) and one main
contactor with 4 main contacts (2x NO and 2x NC) are used for the motor connection. Both contactors
are equipped with 3 auxiliary contacts (1x NO and 2x NC) each for external contactor monitoring.
5.20.1
Activation of the motor contactors (X-K)
The motor contactors integrated in the frequency converter are activated by the lift control. Activation
takes place by applying the operating voltage to the connection terminal X-K (see connection plan).
Information
The power supply of the motor contactors must be fed via the mains
fi
lter of the lift control. If
this is not possible a separate mains
fi
lter (e.g. CORCOM type 3VK1F7135) can be used
alternatively.
Information
Depending on the desing, motor contactors with AC- or DC-voltage will be used. As with the use of
contactors with DC-voltage the recti
fi
eres are already integrated in the inverter, for the activation of the
motor contactors AC-voltage can be applied to the terminal X-K generally.
CAUTION!
Caution!
Note operating voltage of the contactors! A wrong operating voltage can destroy the motor contactors!
Original operating instructions
ZETADYN 3C
Electrical installation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
40/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...