5.10
Motor temperature monitoring (X-MT)
Information
The frequency inverter must be equipped with the option module EM3-MOT-TEMP (item no. 357108)
for motor temperature monitoring!
Information
The detection of over temperature of the motor doesn't cause a drive interruption. The current drive
will be completed.
If an over temperature of the motor will be detected at stop, there is no further drive possible.
The temperature monitoring is carried out according to IEC 61800-5-1:2003-02 (switching point at
3500
Ω
)
The following sensor types can be used:
•
PTC thermistor (PTC according to DIN 44082)
•
Temperature sensor KTY84-130
•
Thermal circuit breaker
The used sensor has to be parametrized in the menue
Monitoring/P1P2
!
Monitor
|
-
"
P1P2
On
|
-
"
On
Motor temp. monitor
P1
P2
X-MT
P1
P2
M
3~
PE
V
W
U
(P1)
(P2)
Temperature monitoring connection
()
terminal designation of connector
Information
If the temperature monitor is not used, it must be switched off
(Monitors/P1P2=Off)
. Short-circuiting
of the inputs P1 and P2 is detected as a fault by the ZETADYN 3C.
Original operating instructions
ZETADYN 3C
Electrical installation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
27/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...