13.6
Operating conditions of the inverter
The frequency inverter software divides the operating curve into various sections. Each of
these sections is assigned a status number that refers to a de
fi
ned service condition.
If an error occurs, the status number is stored with the error number in ther error list.
Furthermore, the operating conditions are displayed with the status number and in plain test in the
Info/Page02
menu.
status
Condition of the inverter
status
Condition of the inverter
10
Checking of voltage supply
430
Constant running at speed V3(time-dependent,
V1 is not activated)
21
Check software version
431
Round down the acceleration to V3 (distance-de-
pendent)
22
Parameter transmission
432
Linear acceleration to V3 (distance-dependent)
30
Check absolute value encoder
433
Constant travel with V3 (distance-dependent)
41
42
Check input BC
41: Power feedback unit
42: Brake chopper or brake resistor
435
Deceleration with safety ramp
50
Adjust current transformer
440
distance dependent travel with DCP4
70
Check temperature power unit
480
Retract to standstill
100
Device off
490
fast stop
105
Power feedback unit on standby
500
Keep motor at speed 0 (T4)
110
Machine ready
510
Wait until motor brakes are closed (T5)
200
Start-up check
515
Brake gets additional current feed for 1s
210 ... 223 Check absolute value encoder
520
Switch off current to motor (T5b)
300
Wait until motor contactors switched on (T0)
530
Wait until motor contactors switched off (T6)
305
Checking the motor phases
535
Travel interrupted due to interruption of the con-
troller enable RF
310
311
Build-up of magnetic
fi
eld in the motor (T1)
536
Travel interrupted due to interruption of the con-
tactor monitor COx
320
Wait until motor brakes have opened (T2)
540
Wait for standstill
330
Accelerate motor to speed V_T3 (T3)
550
Checking the input BR after travel
fi
nished
340
Start up
560
End of travel
400
Accelerate to speed Vx
900
Delay of automatic acknowledgement after reme-
dying the cause of the fault (2 s)
402
Constant running at speed Vx
950
Parameter change
404
Delay from speed Vx
982
Motor type changed
410
Constant running at speed V1
988
Wait for reset
420
Constant running at speed V2
990
Fault input BC
421
Round down the acceleration to V2 (distance-de-
pendent)
991
No absolute value encoder detected
422
Linear acceleration to V2 (distance-dependent)
992
Temperature of the power section missing
423
Constant travel with V2 (distance-dependent)
997
Frequency converter is in stand-by mode
424
Rounding up and linear delay from V2 (distance-
dependent)
998
Wait until frequency converter is switched off
425
Rounding down of the delay from V2 (distance-
dependent)
4xx
2xx
5xx
3xx
Travel curve with related status numbers
Original operating instructions
ZETADYN 3C
Error diagnosis
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
149/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...