![ZIEHL-ABEGG ZETADYN 3C Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/ziehl-abegg/zetadyn-3c/zetadyn-3c_original-operating-instructions_3741629139.webp)
Error no.
Error text
Error cause
M S
328
ENC: Count-Dif
Error:
Too large a difference between the position determined by the absolute
rotary encoder and the position calculated from the encoder pulses
Remedy:
Check the encoder,
Check rotary encoder line
Check encoder connection (e.g. shielding)
329
ENC:Sinus-Error S
Fault:
Plausibility between sine and cosine track of sinus encoder unsatisfac-
tory
Remedy:
Check the encoder,
Check rotary encoder line
Check encoder connection (e.g. shielding)
330
ENC:Sinus-Error F
Fault:
Plausibility between sine and cosine track of sinus encoder unsatisfac-
tory
Number of checks can be set in the menu "S9_ZA-Intern/ENC_C HK". The
factory setting ENC_CHK=4 corresponds to a check duration of approx. 1 ms.
Remedy:
Check the encoder,
Check rotary encoder line
Check encoder connection (e.g. shielding)
331
ENC: Error NDEF
Error:
Start-Bit of the EnDat-protocol is not detected
Remedy:
Check the encoder,
Check rotary encoder line
Check encoder connection (e.g. shielding)
332
ENC: 1387 CD=0
Fault:
input voltages of signal tracks C and D of absolute value encoder type
ERN1387 areboth zero
Remedy:
Check the encoder,
Check rotary encoder line
Check the encoder connection
372
ENC:No Abs.value
Error:
Before starting to move, no absolute value can be read in from encoder
Remedy:
Check encoder connection
●
373
ENC:No Abs.End
Error:
Before starting to move, no absolute value can be read in from encoder
Remedy:
Check encoder connection
●
374
P1P2:short-circuit
Fault:
with parameterised motor temperature monitor "P1P2=PTC" the resist-
ance at the input P1P2 is < 20 ohms
Remedy:
Check connected motor temperature monitor
Check parameterised sensor type in "Monitoring/P1P2" menu
Short-circuit at the X-MT:P1P2 is not permissible
●
375
MOT:Temp.warning
Fault:
motor temperature monitoring has responded at a standstill
Remedy:
Check the temperature sensor connection
remove the cause for the rise in the motor temperature
●
●
377
BRxx:Temp.warning
Error:
The continious braking power of the Brake resistor is exceeded by
150 % within 120 s
A restart will be avoided
Remedy:
Check the con
fi
guration of the BR-type
Check the connected BR
●
●
378
MP: Not active!
Fault:
Mains supply of the power section not active
●
379
MP:Temp.warning
Error:
during startup, the temperature on the power stage is too high
Remedy:
Inverter is overloaded,
repair the cause for the overload
●
●
380
BR: Start-Error
Error:
When the brake monitoring is activated, at least 1 brake monitoring
contact is not connected or is incorrectly connected
Remedy:
Check the functioning (NO or NC) in the monitoring contacts,
check the con
fi
gured number and function of the monitoring contacts in the
"Monitoring" menu,
check the connection of the monitoring contacts
●
385
DCP: Init fail
Error:
Inverter has not received any initialization data from the open loop
control (in DCP03 & DCP04)
Remedy:
Check the DCP line connection,
Check the type of triggering control in the "Control system" menu
Check the elevator control system
●
Original operating instructions
ZETADYN 3C
Error diagnosis
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
139/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...