13.5.4
Error 1xx
•
Hardware con
fi
guration error
•
Software error
Error no.
Error text
Error cause
M S
100
Serial no. missing
Inverter / CU does not have a serial number, e.g. after a component replace-
ment
●
101
System-Error
An internal, defective component was found during a self-test of the inverter
●
110
120
CU: No ID
CU ID no. was not detected:
CU is not present or its ID EEPROM does not reply
●
111
CUSH: No ID
Shunt ID no. was not detected:
Shunt module is not present or its ID EEPROM does not reply
●
113
123
CUEE: No ID
ID No. of the extension card for the encoder is not recognized: extension
module is not present or its ID EEPROM does not reply
●
115
125
SP: No ID
Switching power supply ID no. was not detected: Switching power supply is not
present or its ID EEPROM does not reply
●
116
126
PP: No ID
Power print ID no. was not detected:
Power print is not present or its ID EEPROM does not reply
●
117
127
MP: No ID
The print module ID no. was not detected:
Module Print is not present or its ID EEPROM does not reply
●
121
CUSH: ID-Error
Internal shunt module was detected but there are problems with the shunt
module's informational content
●
140
MP:Unknown IGBT
A unknown IGBT-module was recognized
141
MP: Temp.Sens?
The external temperature sensor for the Modul Print is not recognized
●
150
HW-Con
fl
ict !
Shuntmodul, Power Print and Modul Prind do not match
155
No Analog-Input!
Frequency converter type ZETADYN 3-HY is not equipped with an analogue
input (X-AN)
●
174
CUMT:Not detect
Option module for the temperature monitoring of the motor is nit recognized:
Check the con
fi
guration for rhe temperature monitoring in the "Monitoring"
menu
●
180
UF CTRL=DCP2/4
Error:
DCP2 or DCP4 is entered for the communication between inverter and
elevator contol. This is not possible with Open-Loop-operation
Remedy:
Enter DCP1 or DCP3 for the communication
●
13.5.5
Error 2xx
•
Con
fi
guration error
Error no.
Error text
Error cause
M S
200
Stop input
Error:
A parameter is open while apply a correct travel command (RF + RVx +
Vx)
Remedy:
End parameter inputs
●
201
Motor name plate
Error:
a parameter in the "Motor name plate" menu has not been assigned
Remedy:
Check the parameter in the "Motor name plate" menu,
202
MOT_TYP = ?
Error:
No motor type was selected in the "Motor name plate" menu
Remedy:
Enter in the "Motor name plate"menu
●
203
n* = 0?
Error:
No speed was entered in the "Installation" menu
Remedy:
Enter the speed at V* in the "Installation" menu directly or have it
calculated based on the installation data
●
204
n* > 3*n
Error:
n* was incorrectly calculated due to incorrect installation data (n* >3xn)
Remedy:
Check the installation data for correct entry
●
205
Input duplicated
Error:
two digital inputs are assigned with the same function
Remedy:
Change the function allocation of the digital inputs
●
Original operating instructions
ZETADYN 3C
Error diagnosis
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
136/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...