3.4.1
Storage duration:
The storage duration depends particularly on the electrolytic capacitors because the oxide coating in
the capacitor deteriorates.
Storage duration:
•
12 months at -20 ... +50
°
C
•
24 months at -20 .. +45
°
C
•
36 months at -20 .. +40
°
C
If storage exceeds the stated maximum storage times, you must carry out a reformation of the
capacitors before applying the entire mains voltage to the inverter.
New formation:
To reform, the frequency inverter needs to be connected to reduced voltage for ca. 1 hour (230 VAC
at L1 / L2).
3.5
Disposal & recycling
Disposal must be carried out professionally and environmentally friendly in accordance with the legal
stipulations.
4
Mechanical installation
4.1
General notes
The ZETADYN 3C frequency converter is a closed compact device that is designed for wall mounting
in the machine room or lift shaft. Assembly in the switch cabinet is not necessary.
Danger!
The following points must be complied with during the mechanical installation to avoid causing a defect
in the device due to assembly errors or environmental in
fl
uences:
Before installation
•
Remove the device from the packing and check for any possible shipping damage
•
Dismantle the transport plate, the transport plate can be used as a drilling template
•
Carry out installation only on a clean, level and stable foundation
•
Assemble the device outside of the traf
fi
c area
During installation
•
Mount the device in a torsion free conditions
•
Installation position: vertical, connection terminals (L1, L2, L3) at bottom; no horizontal assembly
•
Mount the device in a torsion free conditions
•
avoid that drilling chips, screws and other foreign bodies reach the interior of the device
•
Maintain the stated minimum clearances to ensure unobstructed cooling- air feed as well as
unobstructed outgoing air discharge (see
fi
g. "Minimum clearances")
Ambient conditions
•
mounting the device on vibrating components is not allowed
•
the device must not be exposed to any shock
•
Prevent humidity
•
Avoid aggressive and conductive materials in the environment
4.1.1
Switch cabinet installation
CAUTION!
Caution!
The device is designed for wall mounting in the machine room or lift shaft. An adequate cooling must
be ensured for assembly in the switch cabinet. The power loss of the device (see chapter
”
Technical
Data
”
) must be taken into account here.
The speci
fi
ed installation position and the minimum distances must be observed when assembling in
the switch cabinet.
Original operating instructions
ZETADYN 3C
Mechanical installation
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
13/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...