11.7
Time-dependent deceleration
Time-dependent deceleration is activated for all speed transitions if the menu
Decelerating/S_ABH =
OFF
.
With the exception of decelerations of:
•
V_3
R
V_1
•
V_2
R
V_1
the decelerations are operated time-dependent. They are independent from the con
fi
gured function of
the parameter
Decelerating / S_ABH
After switching off the current speed preset, the motor is decelerated time-dependent, according to the
con
fi
gured decelerations and round offs, to the highest speed still triggered.
Information
In a time-dependent deceleration, the deceleration paths vary dependent on the speed attained at the
time the deceleration starts. For this reason, time-dependent deceleration only makes sense if
traveling speed is reached during each trip.
11.7.1
Deceleration with reached traveling speed
6
When the switch off point for the traveling speed is reached, the con
fi
gured
fi
nal speed
V_3 has been reached.
Deceleration to V_2 is initiated
7
Switch off point for V_2
Deceleration to V_1 is initiated
8
Positioning speed V_1 is switched off.
Motor continues to decelerate.
9
Speed 0
Output MB is switched off
Brake must operate immediately
The motor continues to be fed with current
10
The current to the motor is switched off
Output RB is switched off
Motor contactors must drop immediately
Time-dependent deceleration with reached traveling speed
RF
Controller enable
V_1
Positioning speed
V_2
Intermediate speed
V_3
Travel Speed
RV1 / RV2
Direction default
RB
Controller ready
MB_Brake
Mechanical brake
Original operating instructions
ZETADYN 3C
Travel options
R-TBA08_03-GB 1619
Part.-No. 00163322-GB
114/204
Содержание ZETADYN 3C
Страница 196: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 196 204...
Страница 197: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 197 204...
Страница 198: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 198 204...
Страница 199: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 199 204...
Страница 200: ...Original operating instructions ZETADYN 3C EU declaration of conformity R TBA08_03 GB 1619 Part No 00163322 GB 200 204...
Страница 203: ...Original operating instructions ZETADYN 3C R TBA08_03 GB 1619 Part No 00163322 GB 203 204...