![YASKAWA U1000 Series Скачать руководство пользователя страница 555](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114555.webp)
B.7 Parameters that Change with the Motor Code Selection (for PM Motors)
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
555
t
B
Table B.23 200 V, 1150 min
-1
Type YASKAWA SST4 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
2402
2403
2405
2406
2408
240A
240B
240D
Voltage Class
V
200
200
200
200
200
200
200
200
Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
Rated Speed
min
-1
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
Motor Rated Power (for PM Motors)
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
E5-03
Motor Rated Current (for PM Motors)
A
1.77
3.44
5.94
9.17
14.79
20.21
27.40
39.0
E5-04
Number of Motor Poles (for PM Motors)
–
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
2.680 1.520 1.071 0.542 0.362 0.295 0.162 0.115
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
30.55 15.29 17.48 11.98 8.60 9.54 5.31 4.44
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
42.71 24.28
22.51
15.51
10.69
13.84
8.26
5.68
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs/rad
313.1 313.1 345.3 342.9 363.8 384.3 379.9 370.2
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/(min
-1
)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum
Voltage
V
190.0 190.0 190.0 190.0 190.0 190.0 190.0 190.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
C5-17
Motor Inertia
kgm
2
0.0022 0.0042 0.0081 0.0133 0.0168 0.027 0.044 0.054
n5-02
Motor
Acceleration
Time
s
0.080 0.081 0.078 0.088 0.066 0.070 0.085 0.071
n8-49
d-Axis Current for High Efficiency
Control (for PM Motors) (OLV/PM)
%
-8.4
-11.0
-10.7
-10.7
-9.4
-22.5
-22.2
-16.7
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
240E
240F
2410
2412
2413
2414
2415
2416
Voltage Class
V
200
200
200
200
200
200
200
200
Rated Power
kW
15
18
22
30
37
45
55
75
Rated Speed
min
-1
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
Motor
Rated
Power
(for
PM
Motors)
kW
15
18.50 22.00 30.00 37.00 45.00 55.00 75.00
E5-03
Motor Rated Current (for PM Motors)
A
55.9
65.4
77.0
103.5
126.0
153.1
188.5
260.4
E5-04
Number of Motor Poles (for PM Motors)
–
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
0.083 0.065
0.052
0.035 0.026 0.019
0.013
0.009
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
3.50 2.92 2.55 2.03 1.59 1.24 0.98 0.70
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
4.23
3.79 3.22 2.46 1.92 1.64 1.37 0.97
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs/rad
364.5 404.5 445.1 444.4 447.3 470.8 422.4 418.3
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/(min
-1
)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum
Voltage
V
190.0 190.0 190.0 190.0 190.0 190.0 190.0 190.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
C5-17
Motor Inertia
kgm
2
0.063 0.113 0.137 0.252 0.304 0.410 0.55 0.82
n5-02
Motor
Acceleration
Time
s
0.061 0.089 0.090 0.122 0.119 0.132 0.145 0.159
n8-49
d-Axis Current for High Efficiency
Control (for PM Motors) (OLV/PM)
%
-13.7
-15.2
-10.9
-9.8
-9.3
-11.5
-17.7
-17.1
SIEP_C710636_02B_1_0.book 555 ページ 2015年11月25日 水曜日 午後4時56分