![YASKAWA U1000 Series Скачать руководство пользователя страница 549](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114549.webp)
B.7 Parameters that Change with the Motor Code Selection (for PM Motors)
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
549
t
B
Table B.18 400 V, 1150 min
-1
Type YASKAWA SSR1 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
1432
1433
1435
1436
1438
143A
143B
143D
143E
Voltage Class
V
400
400
400
400
400
400
400
400
400
Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
Rated Speed
min
-1
1150
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
Motor Rated Power (for PM Motors)
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
15
E5-03
Motor Rated Current (for PM Motors)
A
0.94
1.51
3.00
4.43
7.08
10.10
13.33
19.9
27.8
E5-04
Number of Motor Poles (for PM Motors)
–
6
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
19.320 10.800 4.456
2.044 1.483 1.215 0.660 0.443 0.331
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
194.70 129.20 76.88 48.60 37.58 44.54 26.36 19.10 15.09
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
252.84 160.90 97.52 61.40 47.65 56.26 34.20 24.67 18.56
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs/rad
640.9 654.1 728.8 688.9 702.0
861.5
783.0
762.2
749.6
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/(min
-1
)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum
Voltage
V
380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
C5-17
Motor Inertia
kgm
2
0.0017 0.0023 0.0083 0.0136 0.0171 0.027 0.046 0.055 0.064
n5-02
Motor
Acceleration
Time
s
0.062 0.044 0.080 0.090 0.067 0.072 0.088 0.073 0.062
n8-49
d-Axis Current for High Efficiency
Control (for PM Motors) (OLV/PM)
%
-8.8
-9.9
-9.3
-10.0
-12.8
-12.3
-15.3
-16.7
-14.9
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
143F
1440
1442
1443
1444
1445
1446
1447
1448
Voltage Class
V
400
400
400
400
400
400
400
400
400
Rated Power
kW
18
22
30
37
45
55
75
90
110
Rated Speed
min
-1
1150
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
Motor
Rated
Power
(for
PM
Motors)
kW
18.50 22.00 30.00 37.00 45.00 55.00 75.00 90.00 110.00
E5-03
Motor Rated Current (for PM Motors)
A
31.8
37.2
52.1
64.8
76.6
92.0
127.1
150.5
185.4
E5-04
Number of Motor Poles (for PM Motors)
–
6
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
0.264
0.192
0.140 0.093 0.063
0.051
0.033
0.027
0.015
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
13.32 9.52 8.16 6.13 4.63 3.96 3.03 2.60 1.89
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
18.00 12.60 11.40 9.10 6.15 5.00 5.14 3.28 2.33
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs/rad
842.7 821.8 872.3 857.7 866.6 854.0
823.1
853.4 829.2
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/(min
-1
)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum
Voltage
V
380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
C5-17
Motor Inertia
kgm
2
0.116 0.140 0.259 0.312 0.418 0.56 0.83 0.96 1.61
n5-02
Motor
Acceleration
Time
s
0.091 0.092 0.125 0.122 0.135 0.147 0.161 0.154 0.212
n8-49
d-Axis Current for High Efficiency
Control (for PM Motors) (OLV/PM)
%
-17.9
-15.9
-17.7
-20.1
-13.8
-12.5
-28.8
-13.3
-11.6
SIEP_C710636_02B_1_0.book 549 ページ 2015年11月25日 水曜日 午後4時56分