Table B.16 400 V, 1450 min
-1
Type YASKAWA SSR1 Series IPM Motor
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
1332
1333
1335
1336
1338
133A
133B
133D
133E
133F
Voltage Class
V
400
400
400
400
400
400
400
400
400
400
Rated Power
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18
Rated Speed
min
-1
1450
1450
1450
1450
1450
1450
1450
1450
1450
1450
E5-02
Motor Rated Power (for PM Motors)
kW
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
15
18.50
E5-03
Motor Rated Current (for PM Motors)
A
0.94
1.56
2.81
4.27
6.98
10.21
13.85
19.5
27.4
32.9
E5-04
Number of Motor Poles (for PM Motors)
–
6
6
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
12.760 7.421
4.825
2.656
1.353
0.999
0.713
0.393
0.295
0.223
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
128.60 85.11 58.87 46.42 31.73 26.20 27.06 15.51 12.65
9.87
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
166.96 113.19
80.59
60.32
40.45
30.94
33.45
19.63
15.87
12.40
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs/rad
528.6 544.2 568.5 572.8 562.9
587.6
670.1
612.7
624.6
610.4
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/(min
-1
)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum
Voltage
V
380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
C5-17
Motor Inertia
kgm
2
0.0017 0.0023 0.0043 0.0083 0.0136 0.017 0.027 0.046 0.055 0.064
n5-02
Motor
Acceleration
Time
s
0.098 0.071 0.066 0.087 0.085 0.072 0.084 0.096 0.085 0.080
n8-49
d-Axis Current for High Efficiency
Control (for PM Motors) (OLV/PM)
%
-6.6
-9.2
-13.5
-12.1
-13.7
-10.1
-12.2
-15.5
-15.1
-16.0
No.
Name
Unit
Default Settings
E5-01
Motor Code Selection (for PM Motors)
−
1340
1342
1343
1344
1345
1346
1347
1348
1349
Voltage Class
V
400
400
400
400
400
400
400
400
400
Rated Power
kW
22
30
37
45
55
75
90
110
132
Rated Speed
min
-1
1450
1450
1450
1450
1450
1450
1450
1450
1450
E5-02
Motor
Rated
Power
(for
PM
Motors)
kW
22.00 30.00 37.00 45.00 55.00 75.00 90.00 110.00 132.00
E5-03
Motor Rated Current (for PM Motors)
A
37.6
52.5
63.2
76.4
96.1
124.0
153.1
186.5
226.0
E5-04
Number of Motor Poles (for PM Motors)
–
6
6
6
6
6
6
6
6
6
E5-05
Motor Stator Resistance (r1) (for PM
Motors)
Ω
0.164
0.137 0.093 0.059
0.048
0.028
0.024
0.015
0.011
E5-06
Motor d-Axis Inductance (Ld) (for PM
Motors)
mH
7.90
7.01 5.93 4.17 3.11 2.32 2.20 1.45 1.23
E5-07
Motor q-Axis Inductance (Lq) (for PM
Motors)
mH
10.38 8.68
6.79
5.22
4.55
2.97
3.23
1.88
1.67
E5-09
Motor Induction Voltage Constant 1 (Ke)
(for PM Motors)
mVs/rad
655.4 708.4 739.2 703.0 747.1
639.3
708.0 640.7
677.0
E5-24
Motor Induction Voltage Constant 2 (Ke)
(for PM Motors)
mV/(min
-1
)
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
E1-04
Maximum Output Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-05
Maximum
Voltage
V
380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0 380.0
E1-06
Base Frequency
Hz
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
72.5
E1-09
Minimum Output Frequency
Hz
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
C5-17
Motor Inertia
kgm
2
0.116 0.140 0.259 0.312 0.42 0.56 0.83 0.96 1.61
n5-02
Motor
Acceleration
Time
s
0.122 0.108 0.161 0.160 0.175 0.171 0.213 0.201 0.281
n8-49
d-Axis Current for High Efficiency
Control (for PM Motors) (OLV/PM)
%
-15.7
-11.5
-6.8
-11.5
-14.8
-15.8
-19.6
-14.9
-15.1
SIEP_C710636_02B_1_0.book 547 ページ 2015年11月25日 水曜日 午後4時56分