![YASKAWA U1000 Series Скачать руководство пользователя страница 534](http://html.mh-extra.com/html/yaskawa/u1000-series/u1000-series_technical-manual_907114534.webp)
B.4 Control Mode Dependent Parameter Default Values
534
YASKAWA ELECTRIC
SIEP C710636 02B YASKAWA U1000 Technical Manual
Table B.3 A1-02 (Motor 1 Control Mode) Dependent Parameters and Default Values
No.
Name
Setting Range
Resolution
Control Modes (A1-02)
OLV/PM (5)
AOLV/PM (6)
CLV/PM (7)
b2-01
<14> Default setting value is dependent on the motor code set to parameter E5-01.
<18> Values shown here are for 200 V class drives. Double the value when using a 400 V class drive.
<41> This default value is a calculated as a percentage of the maximum output frequency.
<55> In AOLV/PM and CLV/PM control modes, the setting units and range are expressed as a percent (0.0 to 100.0%) instead of in Hz.
<56> In AOLV/PM and CLV/PM control modes, the setting units and range are expressed as a percent (0.0 to 40.0%) instead of in Hz.
<57> In AOLV/PM and CLV/PM control modes, the setting units and range are expressed as a percent (-100.0 to 100.0%) instead of in Hz.
DC Injection Braking Start Frequency
0.0 to 10.0
0.1
0.5 Hz
1.0%
0.5%
b2-04
DC Injection Braking Time at Stop
0.00 to 10.00
0.01 s
0.00
0.00
0.00
b3-01
Speed Search Selection at Start
0 or 1
–
0
0
1
b3-08
Current Control Gain during Speed Search
(Speed Estimation Type)
0.00 to 6.00
–
0.3
0.3
0.3
b3-14
Bi-Directional Speed Search Selection (Speed
Estimation Type, Speed Estimation 2 Type,
Current Detection 3 Type)
0 or 1
–
–
–
–
b3-24
Speed Search Method Selection
1 to 4
–
2
2
2
b5-15
PID Sleep Function Start Level
0.0 to 400.0
0.1
0.0 Hz
0.0%
0.0%
b6-01
Dwell Reference at Start
0.0 to 400.0
0.0
Hz
0.0% 0.0%
b6-03
Dwell Reference at Stop
0.0 to 400.0
0.1
0.0
Hz
0.0% 0.0%
b8-01
Energy Saving Control Selection
0 or 1
–
–
1
1
b8-02
Energy Saving Gain
0.0 to 10.0
0.1
–
–
–
b8-03
Energy Saving Control Filter Time Constant
0.00 to 10.00
0.01 s
–
–
–
C1-11
Accel/Decel Time Switching Frequency
0.0 to 400.0
0.1
0.0
Hz
0.0% 0.0%
C2-01
S-Curve Time at Accel Start
0.00 to 10.00
0.01 s
1.00
0.20
0.20
C3-01
Slip Compensation Gain
0.0 to 2.5
0.1
–
–
–
C3-02
Slip Compensation Primary Delay Time
0 to 10000
1 ms
–
–
–
C4-01
Torque Compensation Gain
0.00 to 2.50
0.01
0.00
–
–
C4-02
Torque Compensation Primary Delay Time
0 to 10000
1 ms
100
–
–
C5-01
ASR Proportional Gain 1
0.00 to 300.00
0.01
–
10.00
20.00
C5-02
ASR Integral Time 1
0.000 to 10.000
0.001 s
–
0.500
0.500
C5-03
ASR Proportional Gain 2
0.00 to 300.00
0.01
–
10.00
20.00
C5-04
ASR Integral Time 2
0.000 to 10.000
0.001 s
–
0.500
0.500
C5-06
ASR Primary Delay Time Constant
0.000 to 0.500
0.001 s
–
0.016
0.004
C5-07
ASR Gain Switching Frequency
0.0 to 400.0
0.1
–
0.0% 0.0%
C6-02
Carrier Frequency Selection
0 to 4, F
–
1
1
1
d3-01
Jump Frequency 1
0.0 to 400.0
0.0
Hz
0.0% 0.0%
d3-02
Jump Frequency 2
0.0 to 400.0
0.0
Hz
0.0% 0.0%
d3-03
Jump Frequency 3
0.0 to 400.0
0.0
Hz
0.0% 0.0%
d3-04
Jump Frequency Width
0.0 to 20.0
1.0
Hz
1.0% 1.0%
d5-02
Torque Reference Delay Time
0 to 1000
1 ms
–
–
0
E1-04
Maximum Output Frequency
40.0 to 400.0
0.1 Hz
E1-05
Maximum Voltage
0.0 to 377.1
0.1 V
E1-06
Base Frequency
0.0 to 400.0
0.1 Hz
E1-07
Middle Output Frequency
0.0 to 400.0
0.1 Hz
–
–
–
E1-08
Middle Output Frequency Voltage
0.0 to 377.1
0.1 V
–
–
–
E1-09
Minimum Output Frequency
0.0 to 400.0
0.1 Hz
0.0
E1-10
Minimum Output Frequency Voltage
0.0 to 377.1
0.1 V
–
–
–
F1-01
PG 1 Pulses Per Revolution
0 to 60000
1 ppr
–
–
1024
F1-05
PG 1 Rotation Selection
0 or 1
–
–
–
1
F1-09
Overspeed Detection Delay Time
0.0 to 2.0
0.1 s
–
0.0
0.0
L3-36
Vibration Suppression Gain during Acceleration
(with Current Limit)
0.0 to 100.0
–
–
–
–
L3-41
Vibration Suppression Gain during Deceleration
(with Current Limit)
0.0 to 100.0
–
–
–
–
L1-01
Motor Overload Protection Selection
0 to 6
–
4
4
5
L4-01
Speed Agreement Detection Level
0.0 to 400.0
0.1
0.0
Hz
0.0% 0.0%
L4-02
Speed Agreement Detection Width
0.0 to 20.0
0.1
2.0 Hz
4.0%
4.0%
L4-03
Speed Agreement Detection Level (+/-)
-400.0 to 400.0
0.0
Hz
0.0%
0.0%
L4-04
Speed Agreement Detection Width (+/-)
0.0 to 20.0
0.1
2.0 Hz
4.0%
4.0%
L8-18
Software Current Limit Selection
0 to 1
–
0
0
0
L8-38
Carrier Frequency Reduction Selection
0 to 2
–
0
–
0
L8-40
Carrier Frequency Reduction Off Delay Time
0.00 to 2.00
0.01s
0.00
–
0.00
o1-03
Digital Operator Display Selection
0 to 3
–
0
1
1
o1-04
V/f Pattern Display Unit
0 or 1
–
–
1
1
SIEP_C710636_02B_1_0.book 534 ページ 2015年11月25日 水曜日 午後4時56分